Bathtub Spout

  • Made of solid brass casting
  • High-quality chrome plating
  • Durable aerator
  • Projection 19.5 cm
  • Spout dimensions 2.2 x 4.2 cm - 1.7 x 3.5/2.7 cm front
  • Cover plate 5.4 x 7.4 x 1 cm
  • Also suitable for wide bathtub edges
  • 1/2" thread

Versand

  • Versandgewicht: 1 Kg
  • Versandart: Paket

Produktsicherheitsverordnung

Angaben zum Hersteller:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 08.04.2026, 18:41:19

[pdf] Analysebericht-PGES7
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested by X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2017-500Report No.: #2017-500
Herstellernummer: PGES7Manufacturer Number: PGES7
Material Composition
Kupfer Cu 59,713 ± 0,636 57,000 60,000Copper Cu 59.713 ± 0.636 57.000 60.000
Zink Zn 37,963 ± 0,555 37,000 41,500Zinc Zn 37.963 ± 0.555 37.000 41.500
Blei Pb 1,727 ± 0,189 1,600 2,200Lead Pb 1.727 ± 0.189 1.600 2.200
Zinn Sn 0,166 ± 0,131 0,000 0,300Tin Sn 0.166 ± 0.131 0.000 0.300
Eisen Fe 0,127 ± 0,051 0,000 0,300Iron Fe 0.127 ± 0.051 0.000 0.300
Nickel Ni 0,096 ± 0,049 0,000 0,100Nickel Ni 0.096 ± 0.049 0.000 0.100
Aluminium Al 0,000 0,050Aluminum Al 0.000 0.050
Compliance and Material Information
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "Assessment principles for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information on corrosion resistance.
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Footer and Signatures
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, 31. August 2017Hildesheim, August 31, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Engineering & Quality Assurance
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 04/03/2017).

[PDF] Allgemeine Pflegehinweise

Analyseberichte - PGES7 - Version 1
Analysis Report
The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The sample was tested using X-ray fluorescence analysis and produced the following measurement result.
The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided. The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
The tested material meets the requirements of the German Federal Environmental Agency regarding "Assessment principles for metallic materials in contact with drinking water" - UBA positive list. The tested material meets the requirements of the German Federal Environmental Agency regarding "Assessment principles for metallic materials in contact with drinking water" - UBA positive list.
According to the German Federal Environmental Agency, the material complies with standard DIN 50930-6, which addresses corrosion resistance. According to the German Federal Environmental Agency, the material complies with standard DIN 50930-6, which addresses corrosion resistance.
Material and Labeling
Material: CW617N (CuZn40Pb2) Material: CW617N (CuZn40Pb2)
Report No.: #2017-500 Report No.: #2017-500
Manufacturer Number: PGES7 Manufacturer Number: PGES7
EAN: 4250914808612 EAN: 4250914808612
Measurement Results
Measurement No.: 500 Measurement No.: 500
Mode: Alloys Mode: Alloys
Measurement Duration: 8.0s Measurement Duration: 8.0s
Time: 31.08.2017 18:44:09 Time: 31.08.2017 18:44:09
Manufacturer Number: pges7 Manufacturer Number: pges7
User Login: Marc Manusch User Login: Marc Manusch
Material Suggestion: CW617N_CuZn40Pb2 Material Suggestion: CW617N_CuZn40Pb2
Element Analysis

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Element %
±2σ Min
Max
Copper Cu 59,713
±0,636 57,000
60,000
Zinc Zn 37,963
±0,555 37,000
41,500
Lead Pb 1,727
±0,189 1,600
2,200
Tin Sn 0,166
±0,131 0,000
0,300
Iron Fe 0,127
±0,051 0,000
0,300
Nickel Ni 0,096
±0,049 0,000
0,100
Aluminum Al 0,000
Farbe: Chrom