Our High Gloss Chrome redefines the standard. Through a precise multilayer process of polishing, nickel plating, and chrome plating, a flawless "Mirror Finish" is created. The surface impresses with its cool, bluish-silver shine and extreme hardness. Thanks to passing the 24-hour salt spray test (NSS), we guarantee maximum corrosion protection and ...

Bathtub Mixer

  • Made of solid brass
  • High-quality chrome finish
  • Premium ceramic cartridge tested and approved according to KTW guidelines (drinking water regulation)
  • Durable aerator
  • Includes diverter for hand showers
  • Backflow prevention compliant with DIN EN 1717
  • 1/2" connections
  • Center distance 15 cm ± 2 cm

Versand

  • Versandgewicht: 3.2 Kg
  • Versandart: Paket

Produktsicherheitsverordnung

Angaben zum Hersteller:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 08.04.2026, 18:41:19

[pdf] PGVM23
Components
Nr. Komponente Anzahl 1 Armatur 1 2 Dichtung 2 3 Blende 2 4 S-Anschluss 2 Zertifikat unter: 5 www.paulgurkesshop.de 0No. Component Quantity 1 Faucet 1 2 Seal 2 3 Cover 2 4 S-Connector 2 Certificate under: 5 www.paulgurkesshop.de 0
Technical Data Ceramic Cartridge
Technische Daten Keramikkartusche KTW-Zulassung für Trinkwasser Empfohlener Druck 1-5 Bar Öffnungswinkel 25° Maximale Temperatur 90° Lebensdauer 70.000 Zyklen (EN 817) Rotation 90°Technical Data Ceramic Cartridge KTW approval for drinking water Recommended pressure 1-5 bar Opening angle 25° Maximum temperature 90° Lifespan 70,000 cycles (EN 817) Rotation 90°
Operation
Bedienung • Regeln Sie die Intensität des Wassers mit dem Griff wie in der Abbildung zu sehen. • Regeln Sie die Temperatur des Wassers durch Anwinkeln des Griffes wie abgebildet. 25° 110° warm kalt Umsteller UmstellerOperation • Regulate the intensity of the water with the handle as shown in the picture. • Regulate the temperature of the water by angling the handle as shown. 25° 110° warm cold Diverter Diverter
Installation Steps
Installationsschritte • Umwickeln Sie die S-Anschlüsse mit Teflonband oder Hanf um diese abzudichten. Drehen Sie diese in die vorhandenen Anschlüsse der Wand. • Montieren Sie die Blenden. • Spülen Sie die Leitung mindestens zwei Minuten, bevor Sie die Armatur an die S-Anschlüsse anschließen.Installation Steps • Wrap the S-connectors with Teflon tape or hemp to seal them. Turn them into the existing wall connections. • Mount the covers. • Flush the line for at least two minutes before connecting the faucet to the S-connectors.
Cleaning & Maintenance
Säuberung & Wartung Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten: • Mit sauberem Wasser abspülen & mit Mikrofasertuch trocknen. • Schmutz nur mit milden Reinigungsmitteln entfernen. • Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc. • Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife.Cleaning & Maintenance To ensure consistent quality, the following should be observed: • Rinse with clean water & dry with a microfiber cloth. • Only remove dirt with mild detergents. • Do not use scouring milk, polishing paste, paper towels, etc. • Do not use acidic cleaning agents or soap.
PaulGurkes Quality
PaulGurkes Qualität • Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. • Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. • Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns. Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.PaulGurkes Quality • Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and made using high-quality materials. • Each product undergoes a hand-picked quality control. • If you are not satisfied with our products, please contact us. We reserve the right to make updates, changes or additions to the information and data provided.
[pdf] Analysebericht-PGVM23
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Bericht-Nr.: #2017-347 Herstellernummer: PGVM23 EAN: 4250914806175Report No.: #2017-347 Manufacturer No.: PGVM23 EAN: 4250914806175
Material Composition Table
Element % ± 2σ Min Max Kupfer Cu 59,862 ± 0,644 57,000 60,000 Zink Zn 38,135 ± 0,555 37,000 41,500 Blei Pb 1,786 ± 0,186 1,600 2,200 Eisen Fe 0,196 ± 0,057 0,000 0,300 Zinn Sn 0,000 ± 0,182 0,000 0,300 Nickel Ni 0,000 ± 0,043 0,000 0,100 Aluminium Al 0,000 0,050Element % ± 2σ Min Max Copper Cu 59.862 ± 0.644 57.000 60.000 Zinc Zn 38.135 ± 0.555 37.000 41.500 Lead Pb 1.786 ± 0.186 1.600 2.200 Iron Fe 0.196 ± 0.057 0.000 0.300 Tin Sn 0.000 ± 0.182 0.000 0.300 Nickel Ni 0.000 ± 0.043 0.000 0.100 Aluminum Al 0.000 0.050
Compliance Statements
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "Assessment basis for metallic materials in contact with drinking water" - UBA positive list. According to the German Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information regarding corrosion resistance.
Material Designation
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Signatures and Date
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Technology & Quality Assurance
Umweltbundesamt Reference
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on April 3, 2017).

[PDF] Allgemeine Pflegehinweise

Analyseberichte - PGVM23 - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. The sample was tested using X-ray fluorescence analysis and provided the following measurement result. The suitability for drinking water installations in accordance with the Drinking Water Ordinance (TrinkwV 2001) is hereby proven. The tested material meets the requirements of the Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material complies with the standard DIN 50930-6, which provides statements regarding corrosion resistance.
Material and Report
Werkstoff: CW617N (CuZn40Pb2) Material: CW617N (CuZn40Pb2)
Bericht-Nr.: #2017-347 Report No.: #2017-347
Herstellernummer: PGVM23 Manufacturer Number: PGVM23
EAN: 4250914806175 EAN: 4250914806175
Measurement Results
Analysenbericht XL2-99147 Analysis Report XL2-99147
Messung Nr.: 363 Measurement No.: 363
Modus: Legierungen Mode: Alloys
Messdauer: 10,6s Measurement Duration: 10.6s
Zeit: 03.04.2017 15:46:54 Time: 03.04.2017 15:46:54
Herstellernummer: pgvm23 Manufacturer Number: pgvm23
Werkstoffvorschlag: CW617N_CuZn40Pb2 Material Suggestion: CW617N_CuZn40Pb2
Element Analysis
Element Element
% %
± 2σ ± 2σ
Min Min
Max Max

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Ablaufgarnitur: Ohne Ablaufgarnitur
Anschluss: Hochdruck - druckfest
Anschlussart: Anschlussmaß 150 mm
Anwendung: Kalt- und Warmwasserversorgung
Anwendungsbereich: Badewanne
Artikeltyp: Armatur
Ausführung: Badarmatur
Material: Messing
Merkmal: Keramikkartusche
Montageart: Aufputz Wandmontage
Oberfläche: Glänzend
Variante: Einhebel Badewannenarmatur
Farbe: Chrom
Form: Eckig
Serie: Titan

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Laden...

3D-Modell wird geladen...

Maus: Drehen | Scrollen: Zoom | Rechtsklick: Verschieben Finger: Drehen | Pinch: Zoom | Zwei Finger: Verschieben