  • Protect the supply lines against backflow using an appropriate safety device.

Mixer

  • Made of solid brass
  • Chrome-plated
  • Durable ceramic cartridge from SEDAL
  • Oval design
  • 1/2" thread
  • 1 outlet

Note

This item features an integrated base body and is delivered ready for installation; no additional components are required.

Hand Shower

  • Made of high-quality plastic, chrome-plated
  • Length 11 cm
  • Function: Water flows only when the button is pressed
  • Do not leave under constant pressure

Wall Connection with Holder

  • Made of solid brass
  • High-quality chrome finish
  • Holder angle is fixed
  • Cover Ø 5.7 cm
  • Backflow protection according to DIN EN 1717
  • 1/2" external thread
  • Compatible with all standard shower hoses 1/2"

Shower Hose

  • Kink-resistant, durable, flexible stainless steel hose
  • Brass cone and hex nut, high-quality chrome-plated
  • Cone with rubber protection
  • Length 120 cm
  • 1/2" thread

Versand

  • Versandgewicht: 2.06 Kg
  • Versandart: Paket

Produktsicherheitsverordnung

Angaben zum Hersteller:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 26.06.2026, 22:21:24

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Weitere Kundenbilder zu im Set enthaltenen Produkten

PaulGurkes Concealed Shower Mixer Single Lever Oval

PGFA34K

€89.00*

PaulGurkes Round Wall Connector with Shower Holder

PGHPWAB002

€39.00*

PaulGurkes Shower Hose Swivel Cone 120cm Bidet Hose Silver Metal Hose 1.2m

PGMBS120

€19.90*

PaulGurkes Concealed Bidet Mixer with Oval Hand Shower

[pdf] Allgemeine-Hinweise-UP-Bidet
Installation Instructions
Hinweise zur Installation Unterputz Bidet-SetsInstallation Instructions Concealed Bidet Sets
System Overview & Operation
1. Systemübersicht & Bedienung Das Set besteht aus einer Mischer-Armatur und einer Spraybrause, die den Wasserfluss per Daumendruck temporär freigibt.1. System Overview & Operation The set consists of a mixer fitting and a spray hose that temporarily releases the water flow by thumb pressure.
Important End User Notice
Wichtiger Endkundenhinweis: Die Absperrung an der Handbrause dient nur der kurzzeitigen Unterbrechung. Nach der Nutzung muss die Duscharmatur zwingend geschlossen werden, um den Brauseschlauch vom Leitungsdruck zu entlasten.Important End User Notice: The shut-off on the hand shower is only for a brief interruption. After use, the shower valve must be closed to relieve the shower hose from the line pressure.
Drinking Water Protection & Safety
2. Trinkwasserschutz & Absicherung Bidet-Anlagen erfordern den Schutz vor gesundheitsgefährdendem Wasser (Flüssigkeitskategorie 5 nach DIN EN 1717). Folgende Sicherungsmaßnahmen sind zwingend erforderlich:2. Drinking Water Protection & Safety Bidet systems require protection against hazardous water (fluid category 5 according to DIN EN 1717). The following safety measures are mandatory:
Prevention of Cross-Flow (Overflow)
Vermeidung von Fehlzirkulation (Überströmen): Ist die Armatur geöffnet, der Wasserfluss aber an der Handbrause blockiert, stehen Kalt- und Warmwasser im Mischergehäuse in direkter Verbindung. Um ein Überströmen zwischen den Netzleitungen bei Druckschwankungen zu verhindern, müssen Rückflussverhinderer (RV) an den Kalt- und Warmwasserzuläufen installiert werden.Prevention of Cross-Flow (Overflow): If the fitting is open, but the water flow is blocked at the hand shower, cold and hot water are in direct connection in the mixing housing. To prevent overflow between the mains pipes in case of pressure fluctuations, check valves (RV) must be installed on the cold and hot water inlets.
Protection against Backflow
Schutz vor Rückfließen: Die hier verwendete Duscharmatur ist nicht eigensicher. Sie verfügt über keine integrierte Vorrichtung gegen das Rücksaugen von Schmutzwasser bei Unterdruck. Sichern Sie die Zuleitungen zwingend durch eine geeignete externe Sicherungseinheit ab (i. d. R. Rohrunterbrecher Typ DB in Kombination mit RV), um den Normen für Kategorie 5 gerecht zu werden.Protection against Backflow: The shower fitting used here is not inherently safe. It has no integrated device against back-siphoning of dirty water under negative pressure. Secure the supply lines with a suitable external safety unit (usually a pipe interrupter type DB in combination with RV) to comply with the standards for category 5.
Structural Recommendation: Floor Drain
3. Bauliche Empfehlung: Bodenablauf Ein Brauseschlauch, der zeitweise unter vollem Netzdruck steht, stellt bei Fehlbedienung (Armatur wird nicht geschlossen) oder Materialermüdung ein Risiko dar. Wir empfehlen dringend die Installation eines Bodenablaufs im Bereich des Bidets, um im Schadensfall austretendes Wasser sicher abzuleiten und schwere Gebäudeschäden zu vermeiden.3. Structural Recommendation: Floor Drain A shower hose that is temporarily under full mains pressure poses a risk if misused (fitting is not closed) or due to material fatigue. We strongly recommend installing a floor drain in the area of the bidet to safely drain escaping water in the event of damage and to avoid serious structural damage.
Obligations of the Installer
4. Pflichten des Installateurs Als ausführender Handwerker tragen Sie die Verantwortung für eine normgerechte Ausführung:4. Obligations of the Installer As the executing craftsman, you are responsible for a standard-compliant execution:
Recognized Technical Rules
Anerkannte Regeln der Technik: Die Montage muss streng nach Vorgaben der TrinkwV, DIN EN 1717 sowie DIN 1988-100 erfolgen.Recognized Technical Rules: The installation must strictly comply with the requirements of the TrinkwV, DIN EN 1717 and DIN 1988-100.
Professional Installation
Fachgerechte Installation: Die korrekte Dimensionierung und Montage der externen Sicherungseinrichtungen obliegt Ihnen als Fachmann vor Ort.Professional Installation: The correct dimensioning and installation of the external safety devices is your responsibility as a professional on site.
Customer Information
Kundenaufklärung: Der Betreiber ist ausdrücklich auf die Notwendigkeit hinzuweisen, die Hauptarmatur nach jedem Gebrauch zu schließen.Customer Information: The operator must be explicitly informed of the need to close the main valve after each use.
Disclaimer
Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.We reserve the right to make updates, changes or additions to the information and data provided.
Dokumente der im Set enthaltenen Produkte

PGFA34K

[pdf] Analysebericht-PGFA34K
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Bericht-Nr.: #2017-64Report No.: #2017-64
Herstellernummer: PGFA34KManufacturer Number: PGFA34K
Element Composition
Kupfer Cu 61,375 ± 0,486 58,000 63,000Copper Cu 61.375 ± 0.486 58.000 63.000
Zink Zn 37,707 ± 0,425 33,500 41,500Zinc Zn 37.707 ± 0.425 33.500 41.500
Bismut Bi 0,591 ± 0,098Bismuth Bi 0.591 ± 0.098
Blei Pb 0,234 ± 0,070 0,200 1,400Lead Pb 0.234 ± 0.070 0.200 1.400
Eisen Fe 0,081 ± 0,034 0,000 0,300Iron Fe 0.081 ± 0.034 0.000 0.300
Zinn Sn 0,000 0,500Tin Sn 0.000 0.500
Aluminium Al 0,300 0,900Aluminum Al 0.300 0.900
Nickel Ni 0,000 0,200Nickel Ni 0.000 0.200
Mangan Mn 0,000 0,050Manganese Mn 0.000 0.050
Silizium Si 0,000 0,050Silicon Si 0.000 0.050
Compliance Statements
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the Federal Environment Agency regarding the "Assessment bases for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information on corrosion resistance.
Werkstoff: CC575S (CuZn39Pb1Al)Material: CC575S (CuZn39Pb1Al)
Footer Information
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Engineering & Quality Assurance
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 04/03/2017).
Analyseberichte - PGFA34K - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. The sample was tested using X-ray fluorescence analysis and yielded the following measurement result. The proof of suitability for drinking water installations according to the Drinking Water Regulation (TrinkwV 2001) is thus established. The tested material complies with the requirements of the German Federal Environment Agency regarding "Evaluation criteria for metallic materials in contact with drinking water" - UBA positive list. The material complies with standard DIN 50930-6 according to the German Federal Environment Agency, which specifies information regarding corrosion resistance.
Material Data
Werkstoff: CC575S (CuZn39Pb1Al) Material: CC575S (CuZn39Pb1Al)
Bericht-Nr.: #2017-64 Report No.: #2017-64
Herstellernummer: PGFA34K Manufacturer Number: PGFA34K
EAN: 4250914801361 EAN: 4250914801361
Klingenbergstr. 12 31139 Hildesheim Klingenbergstr. 12 31139 Hildesheim
Measurement Data
Analysenbericht XL2-99147 Analysis Report XL2-99147
Messung Nr.: 64 Measurement No.: 64
Modus: Legierungen Mode: Alloys
Messdauer: 11,6s Measurement Duration: 11.6s
Zeit: 10.03.2017 10:05:10 Time: 10.03.2017 10:05:10
Herstellernummer PGFA34K Manufacturer Number PGFA34K
User Login Marc Manusch User Login Marc Manusch
Werkstoffvorschlag: CC575S_CuZn39Pb1Al Material Suggestion: CC575S_CuZn39Pb1Al
Element Analysis
Kupfer Cu: 61,375 ± 0,486 % (Min: 58,000 - Max: 63,000) Copper Cu: 61.375 ± 0.486 % (Min: 58.000 - Max: 63.000)
Zink Zn: 37,707 ± 0,425 % (Min: 33,500 - Max: 41,500) Zinc Zn: 37.707 ± 0.425 % (Min: 33.500 - Max: 41.500)
Bismut Bi: 0,591 ± 0,098 % Bismuth Bi: 0.591 ± 0.098 %
Blei Pb: 0,234 ± 0,070 % (Min: 0,200 - Max: 1,400) Lead Pb: 0.234 ± 0.070 % (Min: 0.200 - Max: 1.400)
Eisen Fe: 0,081 ± 0,034 % (Min: 0,000 - Max: 0,300) Iron Fe: 0.081 ± 0.034 % (Min: 0.000 - Max: 0.300)
Zinn Sn: 0,000 % (Min: 0,000 - Max: 0,500) Tin Sn: 0.000 % (Min: 0.000 - Max: 0.500)
Aluminium Al: 0,300 % (Min: 0,000 - Max: 0,900) Aluminium Al: 0.300 % (Min: 0.000 - Max: 0.900)
Nickel Ni: 0,000 % (Min: 0,000 - Max: 0,200) Nickel Ni: 0.000 % (Min: 0.000 - Max: 0.200)
Mangan Mn: 0,000 % (Min: 0,000 - Max: 0,050) Manganese Mn: 0.000 % (Min: 0.000 - Max: 0.050)
Silizium Si: 0,000 % (Min: 0,000 - Max: 0,050) Silicon Si: 0.000 % (Min: 0.000 - Max: 0.050)
Signatures and Date
Hildesheim, Montag, 3. April 2017 Hildesheim, Monday, April 3, 2017
Marc Manusch - Leitung Technik & Qualitätswesen Marc Manusch - Head of Technology & Quality Management
Olaf Manusch - Geschäftsführer Olaf Manusch - Managing Director
References
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser", (abgerufen am 03.04.2017). German Federal Environment Agency: "Evaluation Criteria for Metallic Materials in Contact with Drinking Water", (accessed April 3, 2017).

PGHPWAB002

[pdf] Analysebericht-PGHPWAB002
Analysis Report
AnalyseberichtAnalysis Report
Introduction
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Report Details
Bericht-Nr.:Report No.:
Herstellernummer:Manufacturer number:
Material Composition
Element % ± 2σ Min Max Kupfer Cu 57,999 ± 0,680 57,000 60,000 Zink Zn 39,275 ± 0,605 37,000 41,500 Blei Pb 2,270 ± 0,225 1,600 2,200 Eisen Fe 0,238 ± 0,066 0,000 0,300 Zinn Sn 0,127 ± 0,098 0,000 0,300 Nickel Ni 0,076 ± 0,049 0,000 0,100 Aluminium Al 0,000 0,050Element % ± 2σ Min Max Copper Cu 57.999 ± 0.680 57.000 60.000 Zinc Zn 39.275 ± 0.605 37.000 41.500 Lead Pb 2.270 ± 0.225 1.600 2.200 Iron Fe 0.238 ± 0.066 0.000 0.300 Tin Sn 0.127 ± 0.098 0.000 0.300 Nickel Ni 0.076 ± 0.049 0.000 0.100 Aluminum Al 0.000 0.050
Compliance with Drinking Water Regulations
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Compliance with Environmental Agency Requirements
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "assessment basis for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information regarding corrosion resistance.
Material
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Signatures
Olaf Marmusch GeschäftsführerOlaf Marmusch Managing Director
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Technology & Quality Assurance
Source
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on April 3, 2017).
Analyseberichte - PGHPWAB002 - Version 1
Manufacturer Information
Manufacturer PaulGurkes GmbH
Address Klingenbergstr. 12
City and Postal Code 31139 Hildesheim
Analysis Report
Analysis Report XL2-99147
Measurement No. 693
Mode Alloys
Measurement Duration 6.9s
Time 29.09.2017 17:42:17
Manufacturer Number pghpwab002 - body
User Login Marc Manusch
Material Suggestion CW617N_CuZn40Pb2
Element Analysis
Element % | ± | | Min | Max
Copper Cu 57.999 | ± | 0.680 | 57.000 | 60.000
Zinc Zn 39.275 | ± | 0.605 | 37.000 | 41.500
Lead Pb 2.270 | ± | 0.225 | 1.600 | 2.200
Iron Fe 0.238 | ± | 0.066 | 0.000 | 0.300
Tin Sn 0.127 | ± | 0.098 | 0.000 | 0.300
Nickel Ni 0.076 | ± | 0.049 | 0.000 | 0.100
Aluminum Al 0.000 | | | | 0.050
Analyseberichte - PGHPWAB002 - Version 1
Analysis Report
The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is hereby provided. The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is hereby provided.
The tested material complies with the requirements of the Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. The tested material complies with the requirements of the Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list.
According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which sets out statements regarding corrosion resistance. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which sets out statements regarding corrosion resistance.
Material
CW617N (CuZn40Pb2) CW617N (CuZn40Pb2)
Report and Identification Numbers
Report No.: #2017-693 Report No.: #2017-693
Manufacturer No.: PGHPWAB002 Manufacturer No.: PGHPWAB002
EAN: 4250914808674 EAN: 4250914808674
Analysis Report: XL2-99147 Analysis Report: XL2-99147
Measurement No.: 693 Measurement No.: 693
Measurement Results
Element % | ± 2σ | Min | Max
Copper Cu 57,999 | ± 0,680 | 57,000 | 60,000
Zinc Zn 39,275 | ± 0,605 | 37,000 | 41,500
Lead Pb 2,270 | ± 0,225 | 1,600 | 2,200
Iron Fe 0,238 | ± 0,066 | 0,000 | 0,300
Tin Sn 0,127 | ± 0,098 | 0,000 | 0,300
Nickel Ni 0,076 | ± 0,049 | 0,000 | 0,100
Aluminum Al 0,000 | | | 0,050
Measurement Information
Mode: Alloys Mode: Alloys
Measurement Time: 6.9 s Measurement Time: 6.9 s
Time: 29.09.2017 17:42:17 Time: 29.09.2017 17:42:17
Material Suggestion: CW617N_CuZn40Pb2 Material Suggestion: CW617N_CuZn40Pb2
User Login: Marc Manusch User Login: Marc Manusch
Company Information
PaulGurkes GmbH PaulGurkes GmbH
Klingenbergstr. 12 Klingenbergstr. 12
31139 Hildesheim 31139 Hildesheim
Approvals and Date
Managing Director: Olaf Manusch Managing Director: Olaf Manusch
Head of Engineering & Quality Management: Marc Manusch Head of Engineering & Quality Management: Marc Manusch
Date: Hildesheim, Monday, April 3, 2017 Date: Hildesheim, Monday, April 3, 2017

[PDF] Allgemeine Pflegehinweise
Farbe: Chrom

1 of 1 reviews

Average rating of 5 out of 5 stars


100%

0%

0%

0%

0%


Leave a review!

Share your experiences with other customers.


1 review

April 22, 2020 - Joachim Scherzinger 🇩🇪 Deutschland
Verifizierter Kauf

Review with rating of 5 out of 5 stars

Very satisfied☆☆☆☆☆
KI-übersetzt (Originalsprache: de-DE) Original anzeigen
Laden...

3D-Modell wird geladen...

Maus: Drehen | Scrollen: Zoom | Rechtsklick: Verschieben Finger: Drehen | Pinch: Zoom | Zwei Finger: Verschieben