Skip to main content Skip to search Skip to main navigation
Bewertungsdurchschnitt mit

Average rating of 4.9 out of 5 stars

(4.91/5.00) aus insgesamt 2948 Bewertungen

Concealed Thermostat Mixer

The mixer is delivered in standard configuration with a 2-way trim (rain shower / hand shower). To use two outlets, the concealed base unit must be connected accordingly.

  • Made of solid brass
  • High-quality chrome finish
  • Suitable for 2 outlets, e.g., rain shower and hand shower or bathtub filler
  • Switching between outlets by turning the diverter
  • Required base unit PGBASIC
  • Durable thermostat cartridge
  • Safety lock at 38 °C protects against accidentally hot temperatures (scald protection)

Note

This item requires the following accessory:

  • Base unit - Manufacturer number: PGBASIC - EAN: 4250914808827

Versand

  • Versandgewicht: 2.02 Kg
  • Versandart: Paket

Produktsicherheitsverordnung

Angaben zum Hersteller:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 13.05.2026, 20:07:40

[pdf] PGTHR23W-G-v1.0
Components List
Komponenten Nr. Komponente Anzahl 1 Kappe 1 2 Schraube 2 3 Griff 1 4 Pin 1 5 * Blende 0 6 Dichtung 2 7 Schraube 4 8 Fliesenspiegel 1 9 Dichtung 1 10 Armatur 1 11 Dichtungen 7 12 Schlüssel 1 13 Anleitung 1 Zertifikat unter: 14 www.paulgurkesshop.de 1 15 Schlüssel 2 * Je nach Modell (rund, eckig)Components No. Component Quantity 1 Cap 1 2 Screw 2 3 Handle 1 4 Pin 1 5 * Cover Plate 0 6 Seal 2 7 Screw 4 8 Tile Mirror 1 9 Seal 1 10 Fixture 1 11 Seals 7 12 Key 1 13 Instructions 1 Certificate under: 14 www.paulgurkesshop.de 1 15 Key 2 * Depending on the model (round, angular)
Information
Information • Diese Armatur kann für 1-3 Verbraucher genutzt werden. • Schließen Sie die Verbraucher gemäß der Anleitung des Grundkörpers „PGBASIC" an.Information • This fitting can be used for 1-3 consumers. • Connect the consumers according to the instructions for the "PGBASIC" base unit.
Installation Steps
Installationsschritte • Nach der Installation der Unterputz-Box und Prüfung auf Dichtheit ist das Wasser abzustellen. • Entfernen Sie den Schutz der Box. Montieren Sie die Armatur wie im zweiten Schaubild. • Ziehen Sie die Schrauben fest an, vergessen Sie die O-Ringe nicht. • Montieren Sie nun die Abdeckungen wie im dritten Bild. Justieren Sie die Abdeckung, bevor Sie diese fixieren. • Installieren Sie die Blende der Armatur wie im letzten Installationsbild. • Montieren Sie nun den Rest der Armatur.Installation Steps • After installing the concealed box and checking for leaks, turn off the water. • Remove the protection from the box. Mount the fitting as shown in the second picture. • Tighten the screws firmly, do not forget the O-rings. • Now mount the covers as shown in the third picture. Adjust the cover before fixing it. • Install the cover plate of the fitting as shown in the last picture. • Now assemble the rest of the fitting.
Temperature Control
Temperatur regeln • Regeln Sie die Temperatur wie im unteren Schaubild.Temperature control • Regulate the temperature as shown in the diagram below.
Switching Outlets
Ausgänge schalten • Schalten Sie die Ausgänge der Armatur wie im folgenden Schaubild.Switching Outlets • Switch the outlets of the fitting as shown in the following diagram.
Cleaning & Maintenance
Säuberung & Wartung Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten: • Mit sauberem Wasser abspülen & mit Mikrofasertuch trocknen. • Schmutz nur mit milden Reinigungsmitteln entfernen. • Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc. • Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife.Cleaning & Maintenance To ensure consistent quality, please note the following: • Rinse with clean water and dry with a microfiber cloth. • Only remove dirt with mild detergents. • Do not use scouring milk, polishing paste, paper towels, etc. • Do not use any acidic cleaning agents or soap.
PaulGurkes Quality
PaulGurkes Qualität • Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. • Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. • Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns.PaulGurkes Quality • Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and manufactured using high-quality materials. • Each product undergoes a hand-picked quality control. • If you are not satisfied with our products, please contact us.
Disclaimer
Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.We reserve the right to make updates, changes or additions to the information and data provided.
[pdf] Analysebericht-PGTHR23W-PGTHR-3W
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and the following measurement result was obtained.
Report Information
Bericht-Nr.: #2017-742 Herstellernummer: PGTHR23W / PGTHR-3W EAN: 4250914808841 / 4250914810028Report No.: #2017-742 Manufacturer number: PGTHR23W / PGTHR-3W EAN: 4250914808841 / 4250914810028
Element Composition
Kupfer Cu 60,391 ± 0,428 58,000 63,000Copper Cu 60.391 ± 0.428 58.000 63.000
Zink Zn 38,093 ± 0,378 33,500 41,500Zinc Zn 38.093 ± 0.378 33.500 41.500
Blei Pb 1,196 ± 0,111 0,200 1,400Lead Pb 1.196 ± 0.111 0.200 1.400
Eisen Fe 0,125 ± 0,034 0,000 0,300Iron Fe 0.125 ± 0.034 0.000 0.300
Zinn Sn 0,097 ± 0,057 0,000 0,500Tin Sn 0.097 ± 0.057 0.000 0.500
Nickel Ni 0,053 ± 0,030 0,000 0,200Nickel Ni 0.053 ± 0.030 0.000 0.200
Mangan Mn 0,000 ± 0,045 0,000 0,050Manganese Mn 0.000 ± 0.045 0.000 0.050
Silizium Si 0,000 0,050Silicon Si 0.000 0.050
Aluminium Al 0,300 0,900Aluminum Al 0.300 0.900
Conformance Statement
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Environment Agency regarding the "Assessment principles for metallic materials in contact with drinking water" - UBA positive list. According to the German Environment Agency, the material meets the DIN 50930-6 standard, which makes statements regarding corrosion resistance.
Material Information
Werkstoff: CC575S (CuZn39Pb1Al)Material: CC575S (CuZn39Pb1Al)
Signatures and Date
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, 2. Dezember 2017Hildesheim, December 2, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Engineering & Quality Assurance
Reference
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 04/03/2017).
[pdf] PGTHR23W_Anordnungsplan
Component List

[PDF] Allgemeine Pflegehinweise

Analyseberichte - PGTHR23W - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The suitability for drinking water installations in accordance with the Drinking Water Ordinance (TrinkwV 2001) is thus demonstrated. The tested material complies with the requirements of the German Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the German Federal Environment Agency, the material meets the standard DIN 50930-6, which provides information on corrosion resistance.
Material
Werkstoff CC575S (CuZn39Pb1Al)
Report Number and Manufacturer Number
Report Number: #2017-742
Manufacturer Number: PGTHR23W / PGTHR-3W
EAN: 4250914808841 / 4250914810028
Measurement Results
Analysis Report: XL2-99147
Measurement Number: 742
Mode: Alloys
Measurement Duration: 14.5s
Time: 02.12.2017 11:45:08
Manufacturer Number: pgthr23w
User Login: Marc Manusch
Material Suggestion: CC575S_CuZn39Pb1Al
Element Analysis
Copper Cu: 60.391 ± 0.428 (Min: 58.000 Max: 63.000)
Zinc Zn: 38.093 ± 0.378 (Min: 33.500 Max: 41.500)
Lead Pb: 1.196 ± 0.111 (Min: 0.200 Max: 1.400)
Iron Fe: 0.125 ± 0.034 (Min: 0.000 Max: 0.300)
Tin Sn: 0.097 ± 0.057 (Min: 0.000 Max: 0.500)
Nickel Ni: 0.053 ± 0.030 (Min: 0.000 Max: 0.200)
Manganese Mn: 0.000 ± 0.045 (Min: 0.000 Max: 0.050)
Silicon Si: 0.000 (Min: 0.000 Max: 0.050)
Aluminium Al: (Min: 0.300 Max: 0.900)
Signatories
Managing Director: Olaf Manusch
Head of Technical & Quality Management: Marc Manusch
Address: Klingenbergstr. 12, 31139 Hildesheim
Date and Location: Hildesheim, December 2, 2017
Anordnungspläne - PGTHR23W - Version 1
Product Name
PaulGurkes 2-Way In-Wall Thermostatic Valve Fitting for Base Body PGBASIC
Article Number
PGTHR23W
Manufacturer
PaulGurkes GmbH

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Farbe: Chrom

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Laden...

3D-Modell wird geladen...

Maus: Drehen | Scrollen: Zoom | Rechtsklick: Verschieben Finger: Drehen | Pinch: Zoom | Zwei Finger: Verschieben