Skip to main content Skip to search Skip to main navigation
Bewertungsdurchschnitt mit

Average rating of 4.9 out of 5 stars

(4.91/5.00) aus insgesamt 2914 Bewertungen

Retro Black

Our Retro Black is our interpretation of the popular ORB finish (Oil Rubbed Bronze). This is not just a simple black, but a very dark, antique finish with subtle bronze accents. This surface gives products a handcrafted feel and provides the perfect vintage look without appearing outdated. Elegant, dark, and full of character. keyw...

Concealed Mixer Tap

  • Made of solid brass casting
  • High-quality black finish
  • Durable ceramic cartridge
  • For a single user
  • 1/2" connections
  • Minimum installation depth 56mm
  • Maximum installation depth 80mm

Retro/Nostalgia Bathtub Spout

  • Made of solid brass
  • High-quality color finish
  • White ceramic insert
  • Durable aerator
  • 1/2" connection

Versand

  • Versandgewicht: 2.29 Kg
  • Versandart: Paket

Produktsicherheitsverordnung

Angaben zum Hersteller:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 08.04.2026, 18:39:32

Weitere Kundenbilder zu im Set enthaltenen Produkten

PaulGurkes Concealed Black Retro Single Lever Mixer 1-Way Faucet

PGHPUMNX-QP

€157.90*

PaulGurkes Vintage Bathtub Filler Nostalgia Retro Black Antique

PGMW2-QP

€109.00*

Dokumente der im Set enthaltenen Produkte

PGMW2-QP

[pdf] Analysebericht-PGMW2-QP
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested by X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2019-1045Report No.: #2019-1045
Herstellernummer: PGMW2-QPManufacturer Number: PGMW2-QP
Material Composition
Kupfer Cu 59,819 ± 0,605 57,000 60,000Copper Cu 59.819 ± 0.605 57.000 60.000
Zink Zn 37,507 ± 0,522 37,000 41,500Zinc Zn 37.507 ± 0.522 37.000 41.500
Blei Pb 2,249 ± 0,199 1,600 2,200Lead Pb 2.249 ± 0.199 1.600 2.200
Zinn Sn 0,195 ± 0,100 0,000 0,300Tin Sn 0.195 ± 0.100 0.000 0.300
Eisen Fe 0,103 ± 0,045 0,000 0,300Iron Fe 0.103 ± 0.045 0.000 0.300
Nickel Ni 0,055 ± 0,042 0,000 0,100Nickel Ni 0.055 ± 0.042 0.000 0.100
Aluminium Al 0,000 0,050Aluminum Al 0.000 0.050
Compliance Statement
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The verification of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "assessment principles for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which specifies statements regarding corrosion resistance.
Material Designation
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Footer and Signature
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Montag, 20. Mai 2019Hildesheim, Monday, May 20, 2019
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Technology & Quality Management
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 20.05.2019).Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on May 20, 2019).
Analyseberichte - PGMW2-QP - Version 1
Analysis Report
Analysis Report
The sample was tested using X-ray fluorescence analysis and produced the following measurement results. The evidence of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is hereby established.
The tested material complies with the requirements of the German Federal Environment Agency regarding "Assessment bases for metallic materials in contact with drinking water" - UBA positive list. The material meets the DIN 50930-6 standard according to the German Federal Environment Agency, which outlines statements regarding corrosion resistance.
Material: CW617N (CuZn40Pb2)
Report Number: #2019-1045
Manufacturer Number: PGMW2-QP
EAN: 4250914815337
Signatures
Signatures
Olaf Manusch, Managing Director
Marc Manusch, Head of Engineering & Quality Management
Manufacturer Information
Manufacturer Information
PaulGurkes GmbH
Klingenbergstr. 12
31139 Hildesheim
Measurement Results
Measurement Results
Analysis Report: XL2-99147
Measurement Number: 1045
Mode: Alloys
Measurement Duration: 8.6s
Time: 20.05.2019 11:29:39
Manufacturer Number: pgmw2-qp
User Login: Marc Manusch
Material Designation: CW617N_CuZn40Pb2
Elemental Analysis
Elemental Analysis
Element % ± 2σ Min Max
Copper Cu 59.819 ± 0.605 57.000 60.000
Zinc Zn 37.507 ± 0.522 37.000 41.500
Lead Pb 2.249 ± 0.199 1.600 2.200
Tin Sn 0.195 ± 0.100 0.000 0.300
Iron Fe 0.103 ± 0.045 0.000 0.300
Nickel Ni 0.055 ± 0.042 0.000 0.100
Aluminum Al 0.000 0.050

[PDF] Allgemeine Pflegehinweise
Farbe: Schwarz mit Kupfer

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Laden...

3D-Modell wird geladen...