Skip to main content Skip to search Skip to main navigation
Bewertungsdurchschnitt mit

Average rating of 4.9 out of 5 stars

(4.91/5.00) aus insgesamt 2960 Bewertungen

Concealed Faucet

  • Featuring a high-quality brand ceramic cartridge
  • Includes a 2-way diverter
  • The faucet is made entirely of solid brass
  • Premium chrome finish
  • 1/2" standard internal thread

Operation

  • The upper diverter allows switching between outlets. After turning off the water with the lower single-lever mixer, the diverter returns to its original position. In the rest position, the lower outlet is active.

Note

This item comes with an integrated base body and is ready for installation; no additional components are required.

Shower Head

  • Made of stainless steel
  • High-gloss polished (like chrome)
  • 40 x 40 cm
  • Extra thin up to 2 mm
  • 196 anti-lime nozzles
  • Edges rounded, seamless design
  • Includes ECO flow restrictor max. 10 L/min
  • Flat design allows for immediate water stop
  • With chrome-plated brass ball joint

Supply Arm for Shower Heads

  • Square wall arm
  • Made of solid brass
  • High-quality chrome plating
  • Pipe dimensions 3.5 x 1.5 cm
  • Length 38.5 cm (34.5 cm without thread)
  • 1/2" thread

Wall Connection Elbow

  • Square flat design
  • Made of solid brass
  • High-quality chrome finish
  • Backflow prevention according to DIN EN 1717
  • 1/2" external thread

Shower Holder

  • Square wall mount, flat design
  • Made of solid brass
  • High-quality chrome finish
  • Hole distance: 1.3 ~ 2.3 cm

Hand Shower

  • Square handheld shower
  • Made of solid brass
  • High-quality chrome finish
  • 1 function
  • 44 anti-lime nozzles
  • Length 20.2 cm (21.8 cm with thread)
  • 1.5 x 3.5 cm

Shower Hose Length 150 cm

  • The dual 1/2" swivel cones prevent twisting of the hose
  • High-quality plastic hose with a smooth surface, reinforced with polyester threads (cross-weave)
  • The smooth surface allows for excellent cleaning options
  • The silver-gloss surface achieves a metallic effect
  • Swivel cones made of solid brass, high-quality chrome finish
  • Certified: KTW recommendation, EN 1113, NF077
  • Made in Germany

Versand

  • Versandgewicht: 6.99 Kg
  • Versandart: Paket

Produktsicherheitsverordnung

Angaben zum Hersteller:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 05.06.2026, 07:48:39

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Weitere Kundenbilder zu im Set enthaltenen Produkten

PaulGurkes Concealed Shower Mixer Bathtub Faucet Square with Diverter

PGVM34

€159.00*

PaulGurkes 40cm Stainless Steel Flat Luxury Rain Shower Head

PGHPSSSHE40

€148.00*

PaulGurkes Wall Arm for Rectangular Shower Head

PG9Q

€49.00*

PaulGurkes Wall Connector Elbow Hose Connection Brass Chrome

PGHPBWO005

€29.00*

PaulGurkes Flat Shower Holder in Brass for Adjustable Hand Showers

PGHPBE004

€34.00*

PaulGurkes Square Brass Hand Shower

PGHPBHS009

€37.90*

PaulGurkes 150cm Shower Hose Plastic 1.5m Classic Silver

PGCCS150

€19.59*

Dokumente der im Set enthaltenen Produkte

PGVM34

[pdf] Analysebericht-PGVM34
Analysis Report Header
Analysebericht PaulGurkes GmbHAnalysis Report PaulGurkes GmbH
Introduction
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2017-29 Herstellernummer: PGVM34 EAN: 4250914802368Report No.: #2017-29 Manufacturer Number: PGVM34 EAN: 4250914802368
Element Composition
Element % ± 2σ Min Max Kupfer Cu 59,625 ± 0,330 58,000 61,000 Zink Zn 38,507 ± 0,291 37,000 40,000 Blei Pb 1,685 ± 0,098 1,500 2,500 Eisen Fe 0,049 ± 0,021 0,000 0,310Element % ± 2σ Min Max Copper Cu 59.625 ± 0.330 58.000 61.000 Zinc Zn 38.507 ± 0.291 37.000 40.000 Lead Pb 1.685 ± 0.098 1.500 2.500 Iron Fe 0.049 ± 0.021 0.000 0.310
Suitability Statement
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided.
Material Compliance
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "Assessment principles for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information on corrosion resistance.
Material Designation
Werkstoff: CW617N (CuZn39Pb2)Material: CW617N (CuZn39Pb2)
Signatures
Olaf Manusch Geschäftsführer Hildesheim, Montag, 3. April 2017 Marc Manusch Leitung Technik & QualitätswesenOlaf Manusch Managing Director Hildesheim, Monday, April 3, 2017 Marc Manusch Head of Technology & Quality Assurance
Legal Notice
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 04/03/2017).
[pdf] PGVM34
Komponentenliste
Nr. Komponente AnzahlNo. Component Quantity
1 Unterputzelement 11 Concealed element 1
2 Blende 12 Cover plate 1
4 Madenschraube 14 Grub screw 1
5 Griff 15 Handle 1
6 Umstellerknopf 16 Diverter knob 1
Zertifikat unter: 7 www.PaulGurkesShop.de 1Certificate under: 7 www.PaulGurkesShop.de 1
Technische Daten
Technische Daten KeramikkartuscheTechnical Data Ceramic Cartridge
KTW-Zulassung für TrinkwasserKTW approval for drinking water
Empfohlener Druck 1-5 BarRecommended pressure 1-5 Bar
Öffnungswinkel 25°Opening angle 25°
Maximale Temperatur 90°Maximum temperature 90°
Lebensdauer 70.000 Zyklen (EN 817)Service life 70,000 cycles (EN 817)
Bedienung
Bedienung • Standardmäßig ist der untere Ausgang aktiv. Nach Betätigen des Umstellers der obere Ausgang. • Nach Abstellen des Wassers springt der Umsteller in seine Ausgangsposition zurück.Operation • By default, the lower outlet is active. After actuating the diverter, the upper outlet. • After the water is turned off, the diverter springs back to its starting position.
Montagehinweis
Montagehinweis • Um das Unterputzelement weit genug aus der Wand zu holen, sind zwei 90° 1/2" Winkel geeignet. Die in der Wand verlegten Zuleitungen können dadurch tiefer in der Wand liegen. • Achten Sie insbesondere dadrauf, dass die Verjüngung des Umstellers nach der Installation aus der Abdeckblende hervorschaut und der dickere Teil des Umstellers mit der Blende abdichtet. • Die zwei Zentimeter können für den Fliesenspiegel genutzt werden. Achten Sie insbesondere auf die Einbautiefe von 5,5cm. • Sollte die Armatur zu tief in die Wand gebaut sein, dann ist der Umsteller nicht zu Bedienen. • Sanitärinstallateur und Fliesenleger müssen sich gegenseitig koordinieren, damit die Armatur nicht zu tief in die Wand montiert wird.Installation instructions • To bring the concealed element far enough out of the wall, two 90° 1/2" elbows are suitable. The supply lines laid in the wall can therefore be deeper in the wall. • Pay particular attention to the fact that the narrowing of the diverter protrudes from the cover plate after installation and the thicker part of the diverter seals with the cover plate. • The two centimeters can be used for the tile mirror. Pay particular attention to the installation depth of 5.5cm. • If the fitting is built too deep into the wall, the diverter cannot be operated. • Plumbers and tilers must coordinate with each other so that the fitting is not installed too deep in the wall.
Analyseberichte - PGVM34 - Version 1
Analysis Report
3 1 139 Hildesheim 3 1 139 Hildesheim
Analysenbericht XL2-99147 Analysis Report XL2-99147
Messung Nr.: 29 Measurement No.: 29
Modus: Legierungen Mode: Alloys
Messdauer: 25,5s Measurement Duration: 25.5s
Zeit: 07.03.2017 18:41:37 Time: 07.03.2017 18:41:37
Herstellernummer PGVM34 Manufacturer Number PGVM34
User Login Marc Manusch User Login Marc Manusch
Werkstoffvorschlag: C377ForgBs Material Suggestion: C377ForgBs
Element
Kupfer Cu 59,625 ± 0,330 58,000 61,000 Copper Cu 59.625 ± 0.330 58.000 61.000
Zink Zn 38,507 ± 0,291 37,000 40,000 Zinc Zn 38.507 ± 0.291 37.000 40.000
Blei Pb 1,685 ± 0,098 1,500 2,500 Lead Pb 1.685 ± 0.098 1.500 2.500
Eisen Fe 0,049 ± 0,021 0,000 0,310 Iron Fe 0.049 ± 0.021 0.000 0.310
Measurement Result and Evidence
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. The proof of suitability for drinking water installations according to the Drinking Water Regulation (TrinkwV 2001) is hereby provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA-Positivliste. The tested material complies with the requirements of the German Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list.
Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. According to the Federal Environment Agency, the material meets the standard DIN 50930-6, which addresses statements regarding corrosion resistance.
Material and Documentation
Werkstoff: CW617N (CuZn39Pb2) Material: CW617N (CuZn39Pb2)
Bericht-Nr.: #2017-29 Report No.: #2017-29
Herstellernummer: PGVM34 Manufacturer Number: PGVM34
EAN: 4250914802368 EAN: 4250914802368
Signatures and Date
Olaf Manusch Geschäftsführer Olaf Manusch Managing Director
Hildesheim, Montag, 3. April 2017 Hildesheim, Monday, April 3, 2017
Marc Manusch Leitung Technik & Qualitätswesen Marc Manusch Head of Engineering & Quality Management
References
Umweltbundesamt: „ Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser ", (abgerufen am 03.04.2017). German Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (retrieved 03.04.2017).

PGHPSSSHE40

[pdf] Wartungsplan_Kopfbrause
Maintenance Plan Header
WartungsplanMaintenance Plan
DatumDate
Maintenance Schedule
1. Wartung:1. Maintenance:
2. Wartung:2. Maintenance:
3.. Wartung:3. Maintenance:
4. Wartung:4. Maintenance:
5. Wartung:5. Maintenance:
6. Wartung:6. Maintenance:
7. Wartung:7. Maintenance:
8. Wartung:8. Maintenance:
Disclaimer
Dies gilt nicht als Nachweis der Wartungen!This does not serve as proof of maintenance!
Company Information
Ihr PaulGurkes TeamYour PaulGurkes Team
Introduction to Shower Head Maintenance
Um eine gleichbleibende Qualität und Funktionalität Ihrer Kopfbrause sicherzustellen, ist eine regelmäßige Wartung notwendig. Der je nach Region unterschiedliche Kalkgehalt des Wassers ist dafür verantwortlich, in welchen Intervallen Sie Ihre Kopfbrause entkalken müssen.To ensure consistent quality and functionality of your shower head, regular maintenance is necessary. The lime content of the water, which varies from region to region, is responsible for the intervals at which you have to descale your shower head.
Maintenance Instructions
AnleitungInstructions
1. Prüfen Sie ob die Kopfbrause ein gerades Strahlbild hat.1. Check whether the shower head has a straight spray pattern.
2. Wenn das Strahlbild unruhig fällt ist die Kopfbrause verkalkt. Löser Sie leichte Verkalkungen, indem Sie mit den Fingern während des Duschvorgangs über die Düsen rubbeln.2. If the spray pattern is uneven, the shower head is calcified. Remove slight calcifications by rubbing the nozzles with your fingers during the shower.
3. Prüfen Sie erneut das Strahlbild.3. Check the spray pattern again.
4. Bei starken Verkalkungen oder hartem Wasser ist die Kopfbrause regelmäßig mit geeignetem Kalklöser komplett zu behandeln.4. In case of heavy calcification or hard water, the shower head should be treated regularly with a suitable descaler.
Consequences of Neglecting Maintenance
Wird keine regelmäßige Wartung vorgenommen, kann die Kopfbrause aufgrund der Verkalkung platzen!If regular maintenance is not carried out, the shower head may burst due to calcification!

PG9Q

[pdf] Analysebericht-PG9Q
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2017-383Report No.: #2017-383
Herstellernummer: PG9QManufacturer Number: PG9Q
Elemental Composition Table
Kupfer Cu 61,041 ± 0,989 58,000 63,000Copper Cu 61.041 ± 0.989 58.000 63.000
Zink Zn 37,556 ± 0,854 33,500 41,500Zinc Zn 37.556 ± 0.854 33.500 41.500
Blei Pb 0,990 ± 0,230 0,200 1,400Lead Pb 0.990 ± 0.230 0.200 1.400
Eisen Fe 0,274 ± 0,100 0,000 0,300Iron Fe 0.274 ± 0.100 0.000 0.300
Nickel Ni 0,137 ± 0,080 0,000 0,200Nickel Ni 0.137 ± 0.080 0.000 0.200
Zinn Sn 0,000 ± 0,213 0,000 0,500Tin Sn 0.000 ± 0.213 0.000 0.500
Mangan Mn 0,000 ± 0,078 0,000 0,050Manganese Mn 0.000 ± 0.078 0.000 0.050
Silizium Si 0,000 0,050Silicon Si 0.000 0.050
Aluminium Al 0,300 0,900Aluminum Al 0.300 0.900
Compliance Statement
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "Assessment bases for metallic materials in contact with drinking water"- UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information on corrosion resistance.
Material Designation
Werkstoff: CC757S (CuZn39Pb1Al-C)Material: CC757S (CuZn39Pb1Al-C)
Signatures and Date
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Samstag, 8. April 2017Hildesheim, Saturday, April 8, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Engineering & Quality Management
Footnote
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 03.04.2017).
Analyseberichte - PG9Q - Version 1
Analysis Report
X-Ray Fluorescence Analysis The sample was tested using X-ray fluorescence analysis and provided the following measurement result. The suitability for use in drinking water installations according to the Drinking Water Regulation (TrinkwV 2001) has thus been demonstrated.
Compliance with UBA The tested material complies with the requirements of the Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list.
Standard DIN 50930-6 According to the Federal Environment Agency, the material meets the standard DIN 50930-6, which presents statements regarding corrosion resistance.
Material Data
Material CC757S (CuZn39Pb1Al-C)
Material Proposal CC575S_CuZn39Pb1Al
Manufacturer Number PG9Q
EAN 4250914802436
Report Number #2017-383
Measurement Results
Measurement Number 383
Mode Alloys
Measurement Duration 3.7s
Time 04.08.2017 11:08:56
Element Analysis
Element % ± 2σ Min Max
Copper Cu 61.041 ± 0.989 58.000 63.000
Zinc Zn 37.556 ± 0.854 33.500 41.500
Lead Pb 0.990 ± 0.230 0.200 1.400
Iron Fe 0.274 ± 0.100 0.000 0.300
Nickel Ni 0.137 ± 0.080 0.000 0.200
Tin Sn 0.000 ± 0.213 0.000 0.500
Manganese Mn 0.000 ± 0.078 0.000 0.050
Silicon Si 0.000 0.050
Aluminum Al 0.300 0.900
Company Information
Address Klingenbergstr. 12
City and Postal Code 31139 Hildesheim
Managing Director Olaf Manusch
Head of Engineering & Quality Assurance Marc Manusch
Date Saturday, April 8, 2017

[PDF] Allgemeine Pflegehinweise
Anwendung: Kalt- und Warmwasserversorgung
Anwendungsbereich: Duschkabine
Farbe: Chrom

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Laden...

3D-Modell wird geladen...

Maus: Drehen | Scrollen: Zoom | Rechtsklick: Verschieben Finger: Drehen | Pinch: Zoom | Zwei Finger: Verschieben