Operation

  • The upper switch is used to select the outlets, e.g., hand shower / rain shower. Additionally, the water intensity is adjusted between the switch positions.
  • The lower switch regulates the water temperature. Due to the 38°C scald protection, a higher temperature requires pressing the safety button on the lower control to allow further adjustment of the thermostat.

General Data

  • 2-way thermostat mixer
  • Equipped with a high-quality branded thermostat cartridge
  • Backflow prevention compliant with DIN EN 1717
  • Hot/cold water supply secured with backflow preventer
  • Made of solid brass
  • With high-quality chrome plating
  • Internal thread 1/2"
  • Control elements made of high-quality plastic
  • Installation depth 60-90 mm

Note

This item has an integrated base body and is delivered ready for installation; no additional components are required.

Rain Shower

  • Made of high-gloss stainless steel
  • Polished to a high shine (like chrome)
  • Ø 40 cm
  • Extra thin up to 2 mm
  • 198 anti-calc nozzles
  • Edges rounded, without seams or screws
  • With ECO flow limiter max. 10 L/min
  • Due to the flat design, immediate water stop occurs
  • With ball joint made of brass, chrome-plated

Supply Arm for Head Showers

  • Round design wall arm
  • Made of solid brass
  • High-quality chrome plating
  • Cover with O-ring seal
  • Projection 33 cm
  • 1/2" thread

Wall Connection Elbow

  • Round design
  • Made of solid brass
  • High-quality chrome-plated
  • Backflow prevention compliant with DIN EN 1717
  • 1/2" thread

Hand Shower

  • Round stick shower
  • Made of solid brass
  • High-quality chrome-plated
  • 1 function
  • 56 nozzles
  • Length 18.7 cm
  • Ø 2.4 cm

Shower Holder

  • Round design
  • Made of solid brass
  • High-quality chrome-plated
  • Adjustable angle of the holder
  • Hole distance: 1.3 ~ 2 cm

Shower Hose Length 150 cm

  • The double-sided 1/2" swivel cones prevent twisting of the hose
  • High-quality plastic hose with smooth surface, reinforced with polyester threads (cross-weave)
  • The smooth surface offers excellent cleaning options
  • The silver-gloss surface achieves a metallic effect
  • Swivel cones made of solid brass, high-quality chrome-plated
  • Certified: KTW recommendation, EN 1113, NF077
  • Made in Germany

Versand

  • Versandgewicht: 7.56 Kg
  • Versandart: Paket

Produktsicherheitsverordnung

Angaben zum Hersteller:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 12.05.2026, 06:39:20

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Weitere Kundenbilder zu im Set enthaltenen Produkten

PaulGurkes Concealed Thermostat Shower Valve Round Shower Fixture

PGJW3-2W

€179.00*

PaulGurkes 40cm Luxury Rain Shower Head Round Ceiling Mount Flat Stainless Steel

PGHPSSSHR40

€130.00*

PaulGurkes Wall Arm for Round Shower Heads

PG9E

€33.90*

PaulGurkes Wall Connector Shower Arm Hose Connection Round

PGHPWAB012

€29.90*

PaulGurkes Round Hand Shower Holder in Brass

PGHPBE013

€39.00*

PaulGurkes Round Hand Shower in Chrome Plated Brass

PGHPBHS004

€37.90*

PaulGurkes 150cm Shower Hose Plastic 1.5m Classic Silver

PGCCS150

€19.59*

Dokumente der im Set enthaltenen Produkte

PGJW3-2W

[pdf] Analysebericht-PGJW3-2W
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2017-78Report No.: #2017-78
Herstellernummer: PGJW3-2WManufacturer Number: PGJW3-2W
Material Composition
Kupfer Cu 59,763 ± 0,429 57,000 60,000Copper Cu 59.763 ± 0.429 57.000 60.000
Zink Zn 38,286 ± 0,374 37,000 41,500Zinc Zn 38.286 ± 0.374 37.000 41.500
Blei Pb 1,686 ± 0,124 1,600 2,200Lead Pb 1.686 ± 0.124 1.600 2.200
Zinn Sn 0,114 ± 0,054 0,000 0,300Tin Sn 0.114 ± 0.054 0.000 0.300
Eisen Fe 0,067 ± 0,028 0,000 0,300Iron Fe 0.067 ± 0.028 0.000 0.300
Nickel Ni 0,000 0,100Nickel Ni 0.000 0.100
Aluminium Al 0,000 0,050Aluminum Al 0.000 0.050
Compliance Statements
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency (Umweltbundesamt) regarding the "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides statements regarding corrosion resistance.
Material Designation
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Signatures
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Technology & Quality Assurance
Footer
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on April 3, 2017).
[pdf] PGJW3-2W_Anordnungsplan
Product Identification
Torque Specification
Component List

PGHPSSSHR40

[pdf] Wartungsplan_Kopfbrause
Maintenance Plan Header
WartungsplanMaintenance Plan
DatumDate
Maintenance Schedule
1. Wartung:1. Maintenance:
2. Wartung:2. Maintenance:
3.. Wartung:3. Maintenance:
4. Wartung:4. Maintenance:
5. Wartung:5. Maintenance:
6. Wartung:6. Maintenance:
7. Wartung:7. Maintenance:
8. Wartung:8. Maintenance:
Disclaimer
Dies gilt nicht als Nachweis der Wartungen!This does not serve as proof of maintenance!
Company Information
Ihr PaulGurkes TeamYour PaulGurkes Team
Introduction to Shower Head Maintenance
Um eine gleichbleibende Qualität und Funktionalität Ihrer Kopfbrause sicherzustellen, ist eine regelmäßige Wartung notwendig. Der je nach Region unterschiedliche Kalkgehalt des Wassers ist dafür verantwortlich, in welchen Intervallen Sie Ihre Kopfbrause entkalken müssen.To ensure consistent quality and functionality of your shower head, regular maintenance is necessary. The lime content of the water, which varies from region to region, is responsible for the intervals at which you have to descale your shower head.
Maintenance Instructions
AnleitungInstructions
1. Prüfen Sie ob die Kopfbrause ein gerades Strahlbild hat.1. Check whether the shower head has a straight spray pattern.
2. Wenn das Strahlbild unruhig fällt ist die Kopfbrause verkalkt. Löser Sie leichte Verkalkungen, indem Sie mit den Fingern während des Duschvorgangs über die Düsen rubbeln.2. If the spray pattern is uneven, the shower head is calcified. Remove slight calcifications by rubbing the nozzles with your fingers during the shower.
3. Prüfen Sie erneut das Strahlbild.3. Check the spray pattern again.
4. Bei starken Verkalkungen oder hartem Wasser ist die Kopfbrause regelmäßig mit geeignetem Kalklöser komplett zu behandeln.4. In case of heavy calcification or hard water, the shower head should be treated regularly with a suitable descaler.
Consequences of Neglecting Maintenance
Wird keine regelmäßige Wartung vorgenommen, kann die Kopfbrause aufgrund der Verkalkung platzen!If regular maintenance is not carried out, the shower head may burst due to calcification!

PGHPWAB012

[pdf] Analysebericht-PGHPWAB012
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following results.
Report Details
Bericht-Nr.: #2017-555Report No.: #2017-555
Herstellernummer: PGHPWAB012Manufacturer Number: PGHPWAB012
Elemental Analysis Results
Kupfer Cu 58,119 ± 0,761 57,000 60,000Copper Cu 58.119 ± 0.761 57.000 60.000
Zink Zn 39,598 ± 0,677 37,000 41,500Zinc Zn 39.598 ± 0.677 37.000 41.500
Blei Pb 2,154 ± 0,245 1,600 2,200Lead Pb 2.154 ± 0.245 1.600 2.200
Eisen Fe 0,127 ± 0,060 0,000 0,300Iron Fe 0.127 ± 0.060 0.000 0.300
Zinn Sn 0,000 ± 0,164 0,000 0,300Tin Sn 0.000 ± 0.164 0.000 0.300
Nickel Ni 0,000 ± 0,061 0,000 0,100Nickel Ni 0.000 ± 0.061 0.000 0.100
Aluminium Al 0,000 0,050Aluminum Al 0.000 0.050
Compliance Statement
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency (Umweltbundesamt) regarding the "Assessment principles for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information on corrosion resistance.
Material Designation
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Signatures and Date
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Technology & Quality Assurance
Additional Information
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 04/03/2017).
Analyseberichte - PGHPWAB012 - Version 1
General Information
PaulGurkes GmbH Klingenbergstr. 12 31139 Hildesheim PaulGurkes GmbH Klingenbergstr. 12 31139 Hildesheim
Analysis Report XL2-99147 Analysis Report XL2-99147
Measurement No.: 555 Measurement No.: 555
Mode: Alloys Mode: Alloys
Measurement Duration: 5.5s Measurement Duration: 5.5s
Time: 29.09.2017 16:17:48 Time: 29.09.2017 16:17:48
Manufacturer Number pghpwab012 Manufacturer Number pghpwab012
User Login Marc Manusch User Login Marc Manusch
Material Suggestion: CW617N_CuZn40Pb2 Material Suggestion: CW617N_CuZn40Pb2
Element Analysis
Copper Cu 58.119 ± 0.761 Min: 57.000 Max: 60.000 Copper Cu 58.119 ± 0.761 Min: 57.000 Max: 60.000
Zinc Zn 39.598 ± 0.677 Min: 37.000 Max: 41.500 Zinc Zn 39.598 ± 0.677 Min: 37.000 Max: 41.500
Lead Pb 2.154 ± 0.245 Min: 1.600 Max: 2.200 Lead Pb 2.154 ± 0.245 Min: 1.600 Max: 2.200
Iron Fe 0.127 ± 0.060 Min: 0.000 Max: 0.300 Iron Fe 0.127 ± 0.060 Min: 0.000 Max: 0.300
Tin Sn 0.000 ± 0.164 Min: 0.000 Max: 0.300 Tin Sn 0.000 ± 0.164 Min: 0.000 Max: 0.300
Nickel Ni 0.000 ± 0.061 Min: 0.000 Max: 0.100 Nickel Ni 0.000 ± 0.061 Min: 0.000 Max: 0.100
Aluminum Al 0.000 Max: 0.050 Aluminum Al 0.000 Max: 0.050
Notes
* Please provide text here. * * Please provide text here. *
Analyseberichte - PGHPWAB012 - Version 1

[PDF] Allgemeine Pflegehinweise
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. The sample was tested using X-ray fluorescence analysis and produced the following measurement result.
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Compliance for use in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus proven.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. The tested material complies with the requirements of the German Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list.
Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. According to the German Federal Environment Agency, the material meets the standard DIN 50930-6, which specifies corrosion resistance requirements.
Werkstoff: CW617N (CuZn40Pb2) Material: CW617N (CuZn40Pb2)
Bericht-Nr.: #2017-555 Report No.: #2017-555
Herstellernummer: PGHPWAB012 Manufacturer Number: PGHPWAB012
EAN: 4250914805796 EAN: 4250914805796
Signatories
Olaf Manusch - Geschäftsführer Olaf Manusch - Managing Director
Marc Manusch - Leitung Technik & Qualitätswesen Marc Manusch - Head of Engineering & Quality Management
Company Information
PaulGurkes GmbH PaulGurkes GmbH
Klingenbergstr. 12 Klingenbergstr. 12
Anwendung: Kalt- und Warmwasserversorgung
Anwendungsbereich: Duschkabine
Farbe: Chrom

2 of 2 reviews

Average rating of 5 out of 5 stars


100%

0%

0%

0%

0%


Leave a review!

Share your experiences with other customers.


2 reviews

March 12, 2016 - Matthias Harbart 🇩🇪 Deutschland
Verifizierter Kauf

Review with rating of 5 out of 5 stars

Gladly again, great quality of the items! Processing worked out great
KI-übersetzt (Originalsprache: de-DE) Original anzeigen
April 8, 2015 - Tina Sasse 🇩🇪 Deutschland
Verifizierter Kauf

Review with rating of 5 out of 5 stars

Looks great and the quality (what can be judged unassembled) is also good
KI-übersetzt (Originalsprache: de-DE) Original anzeigen
Laden...

3D-Modell wird geladen...

Maus: Drehen | Scrollen: Zoom | Rechtsklick: Verschieben Finger: Drehen | Pinch: Zoom | Zwei Finger: Verschieben