Concealed Valve 3-Way

  • All components are made of solid brass
  • High-quality chrome finish
  • Durable SEDAL ceramic cartridge
  • 1/2" connections
  • Single lever mixer with 3-way switch
  • For connection to 3 water outlets
  • Minimum installation depth 5 cm

Note

This item comes with an integrated base body and is ready for installation; no additional components are required.

Waterfall Rain Shower

  • Made of solid stainless steel - high gloss
  • 2-way function - rain shower / waterfall
  • Anti-lime nozzles made of silicone
  • 1/2" connections

Wall Connection Bend with Shower Holder

  • Flat design
  • Made of solid brass
  • High-quality chrome finish
  • Backflow prevention according to DIN EN 1717
  • 1/2" external thread

Hand Shower

  • Square stick shower
  • Made of solid brass
  • High-quality chrome finish
  • 1 function
  • 44 anti-lime nozzles
  • Length 20.2 cm (with thread 21.8 cm)
  • 1.5 x 3.5 cm

Shower Hose Length 160 cm

  • Due to the double-sided 1/2" swivel cones, twisting of the hose is impossible. <\/strong><\/li>
  • Made of stainless steel, high gloss polished
Double winding (wrapped overlapping) for high tensile strength Kink-resistant, durable, flexible Swivel cones made of solid brass, high-quality chrome finish Certified: KTW recommendation, EN 1113, NF077 Made in Germany

Versand

  • Versandgewicht: 7.11 Kg
  • Versandart: Paket

Produktsicherheitsverordnung

Angaben zum Hersteller:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 03.08.2026, 09:21:24

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Weitere Kundenbilder zu im Set enthaltenen Produkten

PaulGurkes Waterfall Shower Head with Dual Function Rain Shower

PGHPSSWFE

€299.00*

PaulGurkes Concealed Shower Valve 3-Way Square Mixer

PGVM24

€194.90*

PaulGurkes Wall Connector with Shower Holder, Square Brass Bend

PGHP009

€44.00*

PaulGurkes Square Brass Hand Shower

PGHPBHS009

€37.90*

PaulGurkes Stainless Steel Shower Hose 160cm with Swivel Connectors

PGdoubleAgraff160

€20.85*

Dokumente der im Set enthaltenen Produkte

PGHPSSWFE

[pdf] Wartungsplan_Kopfbrause
Maintenance Plan Header
WartungsplanMaintenance Plan
DatumDate
Maintenance Schedule
1. Wartung:1. Maintenance:
2. Wartung:2. Maintenance:
3.. Wartung:3. Maintenance:
4. Wartung:4. Maintenance:
5. Wartung:5. Maintenance:
6. Wartung:6. Maintenance:
7. Wartung:7. Maintenance:
8. Wartung:8. Maintenance:
Disclaimer
Dies gilt nicht als Nachweis der Wartungen!This does not serve as proof of maintenance!
Company Information
Ihr PaulGurkes TeamYour PaulGurkes Team
Introduction to Shower Head Maintenance
Um eine gleichbleibende Qualität und Funktionalität Ihrer Kopfbrause sicherzustellen, ist eine regelmäßige Wartung notwendig. Der je nach Region unterschiedliche Kalkgehalt des Wassers ist dafür verantwortlich, in welchen Intervallen Sie Ihre Kopfbrause entkalken müssen.To ensure consistent quality and functionality of your shower head, regular maintenance is necessary. The lime content of the water, which varies from region to region, is responsible for the intervals at which you have to descale your shower head.
Maintenance Instructions
AnleitungInstructions
1. Prüfen Sie ob die Kopfbrause ein gerades Strahlbild hat.1. Check whether the shower head has a straight spray pattern.
2. Wenn das Strahlbild unruhig fällt ist die Kopfbrause verkalkt. Löser Sie leichte Verkalkungen, indem Sie mit den Fingern während des Duschvorgangs über die Düsen rubbeln.2. If the spray pattern is uneven, the shower head is calcified. Remove slight calcifications by rubbing the nozzles with your fingers during the shower.
3. Prüfen Sie erneut das Strahlbild.3. Check the spray pattern again.
4. Bei starken Verkalkungen oder hartem Wasser ist die Kopfbrause regelmäßig mit geeignetem Kalklöser komplett zu behandeln.4. In case of heavy calcification or hard water, the shower head should be treated regularly with a suitable descaler.
Consequences of Neglecting Maintenance
Wird keine regelmäßige Wartung vorgenommen, kann die Kopfbrause aufgrund der Verkalkung platzen!If regular maintenance is not carried out, the shower head may burst due to calcification!

PGVM24

[pdf] Analysebericht-PGVM24
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and the following measurement result was obtained.
Report Details
Bericht-Nr.: #2017-50Report No.: #2017-50
Herstellernummer: PGVM24Manufacturer Number: PGVM24
Material Composition Table
Kupfer Cu 59,565 ± 0,440 57,000 60,000Copper Cu 59.565 ± 0.440 57.000 60.000
Zink Zn 38,726 ± 0,386 37,000 41,500Zinc Zn 38.726 ± 0.386 37.000 41.500
Blei Pb 1,588 ± 0,127 1,600 2,200Lead Pb 1.588 ± 0.127 1.600 2.200
Eisen Fe 0,061 ± 0,029 0,000 0,300Iron Fe 0.061 ± 0.029 0.000 0.300
Zinn Sn 0,000 0,300Tin Sn 0.000 0.300
Aluminium Al 0,000 0,050Aluminum Al 0.000 0.050
Nickel Ni 0,000 0,100Nickel Ni 0.000 0.100
Compliance Statements
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Environment Agency regarding the "Assessment bases for metallic materials in contact with drinking water" - UBA positive list. According to the German Environment Agency, the material complies with the DIN 50930-6 standard, which provides information on corrosion resistance.
Material Designation
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Signatures
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Engineering & Quality Assurance
Footer
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 04/03/2017).
[pdf] PGVM24_Anordnungsplan
Komponentenliste
[pdf] PGVM24-v1.0
Components
Nr. Komponente AnzahlNo. Component Quantity
1 Unterputzelement 11 Concealed Element 1
2 Blende 12 Escutcheon 1
3 Pin & Madenschraube 13 Pin & Grub Screw 1
4 Umstellerknopf 14 Diverter Knob 1
5 Madenschraube 15 Grub Screw 1
7 Griff 17 Handle 1
Zertifikat unter: www.paulgurkesshop.deCertificate at: www.paulgurkesshop.de
Technical Data Ceramic Cartridge
Technische Daten KeramikkartuscheTechnical Data Ceramic Cartridge
KTW-Zulassung für TrinkwasserKTW approval for drinking water
Empfohlener Druck 1-5 BarRecommended pressure 1-5 Bar
Öffnungswinkel 25°Opening angle 25°
Maximale Temperatur 90°Maximum temperature 90°
Lebensdauer 70.000 Zyklen (EN 817)Lifespan 70,000 cycles (EN 817)
Operation
BedienungOperation
• Durch drehen der Position des oberen Umstellers kann zwischen den Verbrauchern geschaltet werden. • Regeln Sie die Temperatur und die Intensität wie im unteren Schaubild.• By turning the position of the upper diverter, you can switch between the consumers. • Regulate the temperature and intensity as shown in the diagram below.
Installation Steps
InstallationsschritteInstallation Steps
• Legen Sie die Zuleitungen so, dass diese an die jeweiligen warm/-kaltwasser 1/2" Anschlüsse angeschlossen werden können. • Achten Sie auf die Einbautiefe, sodass der Einhandmischer bedienbar ist. • Fixieren Sie den Unterputzkörper in der Wand, sodass dieser einen festen Sitz hat. • Montieren Sie den Griff.• Lay the supply lines so that they can be connected to the respective hot/cold water 1/2" connections. • Pay attention to the installation depth so that the single-lever mixer is operable. • Fix the concealed body in the wall so that it has a firm fit. • Install the handle.
Cleaning & Maintenance
Säuberung & WartungCleaning & Maintenance
Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten: • Mit sauberem Wasser abspülen & mit Mikrofasertuch trocknen. • Schmutz nur mit milden Reinigungsmitteln entfernen. • Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc. • Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife.To ensure consistent quality, the following should be observed: • Rinse with clean water & dry with a microfiber cloth. • Only remove dirt with mild detergents. • Do not use scouring milk, polishing paste, paper towels, etc. • Do not use acidic cleaning agents or soap.
PaulGurkes Quality
PaulGurkes QualitätPaulGurkes Quality
• Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. • Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. • Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns.• Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and manufactured using high-quality materials. • Each product undergoes a hand-picked quality control. • If you are not satisfied with our products, please contact us.
Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.We reserve the right to make updates, changes or additions to the information and data provided.
Analyseberichte - PGVM24 - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. The sample was tested using X-ray fluorescence analysis and produced the following measurement result. This thus demonstrates the suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001). The tested material complies with the requirements of the German Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the German Federal Environment Agency, the material complies with DIN 50930-6, which provides statements on corrosion resistance.
Manufacturer Information
Werkstoff: CW617N (CuZn40Pb2) Material: CW617N (CuZn40Pb2)
Bericht-Nr.: #2017-50 Report No.: #2017-50
Herstellernummer: PGVM24 Manufacturer Number: PGVM24
EAN: 4250914800791 EAN: 4250914800791
PaulGurkes GmbH PaulGurkes GmbH
Klingenbergstr. 12 Klingenbergstr. 12
31139 Hildesheim 31139 Hildesheim
Analysis Report XL2-99147
Messung Nr.: 50 Measurement No.: 50
Modus: Legierungen Mode: Alloys
Messdauer: 14,5s Measurement Duration: 14.5s
Zeit: 10.03.2017 09:43:30 Time: 10.03.2017 09:43:30
Herstellernummer: PGVM24 Manufacturer Number: PGVM24
User Login: Marc Manusch User Login: Marc Manusch
Werkstoffvorschlag: CW617N_CuZn40Pb2 Material Suggestion: CW617N_CuZn40Pb2
Measurement Results
Element: Kupfer (Cu) | %: 59,565 | ±2σ: ±0,440 | Min: 57,000 | Max: 60,000 Element: Copper (Cu) | %: 59.565 | ±2σ: ±0.440 | Min: 57.000 | Max: 60.000
Element: Zink (Zn) | %: 38,726 | ±2σ: ±0,386 | Min: 37,000 | Max: 41,500 Element: Zinc (Zn) | %: 38.726 | ±2σ: ±0.386 | Min: 37.000 | Max: 41.500
Element: Blei (Pb) | %: 1,588 | ±2σ: ±0,127 | Min: 1,600 | Max: 2,200 Element: Lead (Pb) | %: 1.588 | ±2σ: ±0.127 | Min: 1.600 | Max: 2.200
Element: Eisen (Fe) | %: 0,061 | ±2σ: ±0,029 | Min: 0,000 | Max: 0,300 Element: Iron (Fe) | %: 0.061 | ±2σ: ±0.029 | Min: 0.000 | Max: 0.300
Element: Zinn (Sn) | %: 0,000 | Min: 0,300 Element: Tin (Sn) | %: 0.000 | Min: 0.300
Element: Aluminium (Al) | %: 0,000 | Max: 0,050 Element: Aluminum (Al) | %: 0.000 | Max: 0.050
Element: Nickel (Ni) | %: 0,000 | Max: 0,100 Element: Nickel (Ni) | %: 0.000 | Max: 0.100
Signatures and Date
Geschäftsführer: Olaf Manusch Managing Director: Olaf Manusch
Leitung Technik & Qualitätswesen: Marc Manusch Head of Engineering & Quality Assurance: Marc Manusch
Hildesheim, Montag, 3. April 2017 Hildesheim, Monday, April 3, 2017
References
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser", (abgerufen am 03.04.2017). German Federal Environment Agency: "Assessment criteria for metallic materials in contact with drinking water", (accessed 03.04.2017).

[PDF] Allgemeine Pflegehinweise
Anwendung: Kalt- und Warmwasserversorgung
Anwendungsbereich: Duschkabine
Farbe: Chrom