Bathtub Faucet
- Made of solid brass
- High-quality chrome finish
- 1/2" connections
- Includes premium aerator
- With diverter
- Cartridge with ceramic seal tested and approved according to KTW regulations (drinking water ordinance)
Shower Faucet
- Made of solid brass
- High-quality chrome finish
- 1/2" connections
- Backflow prevention compliant with DIN EN 1717
- Cartridge with ceramic seal tested and approved according to KTW regulations (drinking water ordinance)
Sink Faucet
- Made of solid brass
- High-quality chrome finish
- Flexible connection hoses 3/8 inch
- Includes mounting accessories
- Provision for pop-up waste assembly included
- Cartridge with ceramic seal tested and approved according to KTW regulations (drinking water ordinance)
Shipping
- Shipping weight: 7.26 Kg
- Shipping method: Paket
Product Safety Regulation
Manufacturer information:
Name des Herstellers: PaulGurkes GmbH
Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland
Elektronische Adresse: info@paulgurkesshop.de
Letztes Update: 16.10.2026, 19:21:35
Documents of the products included in the set
PGFA23
Components
| |||||
Operation
| |||||
Installation Steps
| |||||
Care Instructions
| |||||
PaulGurkes Quality
| |||||
Disclaimer
| |||||
PGFA33
| Analysebericht | Analysis Report |
| Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. | The sample was tested using X-ray fluorescence analysis and yielded the following measurement results. |
| Bericht-Nr.: | Report No.: |
| Herstellernummer: | Manufacturer number: |
| Kupfer | Copper |
| Zink | Zinc |
| Blei | Lead |
| Zinn | Tin |
| Eisen | Iron |
| Aluminium | Aluminum |
| Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. | The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided. |
| Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der 'Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser'- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. | The tested material complies with the requirements of the Federal Environment Agency regarding the 'Assessment criteria for metallic materials in contact with drinking water' - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information on corrosion resistance. |
| Werkstoff: CW617N (CuZn40Pb2) | Material: CW617N (CuZn40Pb2) |
| Geschäftsführer | Managing Director |
| Leitung Technik & Qualitätswesen | Head of Technology & Quality Assurance |
| Umweltbundesamt: 'Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser', (abgerufen am 03.04.2017). | Federal Environment Agency: 'Assessment basis for metallic materials in contact with drinking water', (accessed on 03.04.2017). |
Components
| |||||||||||||||||
Technical Data Ceramic Cartridge
| |||||||||||||||||
Operation
| |||||||||||||||||
Installation Steps
| |||||||||||||||||
Care Instructions
| |||||||||||||||||
PaulGurkes Quality
| |||||||||||||||||
PGFA16
Product Information
| |||
Components
| |||
Technical Data
| |||
Operation
| |||
Installation Steps
| |||
Installation Notes
| |||
| Analysebericht | Analysis Report |
| Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. | The sample was tested by X-ray fluorescence analysis and yielded the following measurement result. |
| Bericht-Nr.: | Report No.: |
| Herstellernummer: | Manufacturer number: |
| Kupfer | Copper |
| Zink | Zinc |
| Blei | Lead |
| Eisen | Iron |
| Zinn | Tin |
| Aluminium | Aluminum |
| Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. | The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided. |
| Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. | The tested material complies with the requirements of the Federal Environment Agency regarding the "assessment principles for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information on corrosion resistance. |
| Werkstoff: CW617N (CuZn40Pb2) | Material: CW617N (CuZn40Pb2) |
| Olaf Manusch, Geschäftsführer | Olaf Manusch, Managing Director |
| Hildesheim, Montag, 3. April 2017 | Hildesheim, Monday, April 3, 2017 |
| Marc Manusch, Leitung Technik & Qualitätswesen | Marc Manusch, Head of Engineering & Quality |
| Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017). | Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 04/03/2017). |
[PDF] Allgemeine Pflegehinweise
Login