Skip to main content Skip to search Skip to main navigation
Bewertungsdurchschnitt mit

Average rating of 4.9 out of 5 stars

(4.91/5.00) aus insgesamt 2934 Bewertungen

Bathtub Faucet

  • Made of solid brass
  • High-quality chrome finish
  • 1/2" connections
  • Includes premium aerator
  • With diverter
  • Cartridge with ceramic seal tested and approved according to KTW regulations (drinking water ordinance)

Shower Faucet

  • Made of solid brass
  • High-quality chrome finish
  • 1/2" connections
  • Backflow prevention compliant with DIN EN 1717
  • Cartridge with ceramic seal tested and approved according to KTW regulations (drinking water ordinance)

Sink Faucet

  • Made of solid brass
  • High-quality chrome finish
  • Flexible connection hoses 3/8 inch
  • Includes mounting accessories
  • Provision for pop-up waste assembly included
  • Cartridge with ceramic seal tested and approved according to KTW regulations (drinking water ordinance)

Versand

  • Versandgewicht: 7.6 Kg
  • Versandart: Paket

Produktsicherheitsverordnung

Angaben zum Hersteller:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 08.04.2026, 18:20:32

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Weitere Kundenbilder zu im Set enthaltenen Produkten

PaulGurkes Bathtub Mixer Single Lever Oval

PGFA23

€219.00*

PaulGurkes Shower Mixer Wall-Mounted Single Lever Oval

PGFA33

€184.90*

PaulGurkes Single Lever Oval Basin Mixer Tap

PGFA16

€194.90*

Dokumente der im Set enthaltenen Produkte

PGFA23

[pdf] PGFA23-v1.0-pdf
Components
Nr. Komponente Anzahl 1 Armatur 1 2 Blende 2 3 Dichtung 4 4 S-Anschluss 2 Zertifikat unter: 5 www.paulgurkesshop.de 1No. Component Quantity 1 Faucet 1 2 Escutcheon 2 3 Seal 4 4 S-Connector 2 Certificate under: 5 www.paulgurkesshop.de 1
Operation
Bedienung • Regeln Sie die Intensität des Wassers mit dem Griff wie in der Abbildung zu sehen. • Regeln Sie die Temperatur des Wassers wie in der Abbildung zu sehen.Operation • Control the water intensity with the handle as shown in the picture. • Control the water temperature as shown in the picture.
Auf Zu 25° 110° Warm Umsteller Umsteller KaltOpen Close 25° 110° Warm Diverter Diverter Cold
Installation Steps
Installationsschritte • Umwickeln Sie die S-Anschlüsse mit Teflonband oder Hanf um diese abzudichten. Drehen Sie diese in die vorhandenen Anschlüsse der Wand. • Montieren Sie die Blenden. • Spülen Sie die Leitung mindestens zwei Minuten, bevor Sie die Armatur an die S-Anschlüsse anschließen.Installation Steps • Wrap the S-connectors with Teflon tape or hemp to seal them. Screw them into the existing wall connections. • Install the escutcheons. • Flush the line for at least two minutes before connecting the faucet to the S-connectors.
Warm Gewinde- Dichtband SchraubeWarm Thread Seal Tape Screw
Care Instructions
Pflegehinweise • Farbige Oberflächen dürfen in keinem Fall mit scheuernden, ätzenden oder alkoholhaltigen Mitteln gereinigt werden. • Spülen Sie das Produkt mit klarem Wasser ab und trocknen es mit einem Mikrofasertuch.Care Instructions • Colored surfaces must never be cleaned with abrasive, corrosive, or alcohol-containing agents. • Rinse the product with clear water and dry it with a microfiber cloth.
PaulGurkes Quality
PaulGurkes Qualität • Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. • Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. • Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns.PaulGurkes Quality • Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and manufactured using high-quality materials. • Every product undergoes a hand-picked quality check. • If you are not satisfied with our products, please contact us.
Disclaimer
Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.We reserve the right to make updates, changes, or additions to the information and data provided.

PGFA33

[pdf] Analysebericht-PGFA33
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement results.
Bericht-Nr.:Report No.:
Herstellernummer:Manufacturer number:
KupferCopper
ZinkZinc
BleiLead
ZinnTin
EisenIron
AluminiumAluminum
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der 'Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser'- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the Federal Environment Agency regarding the 'Assessment criteria for metallic materials in contact with drinking water' - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information on corrosion resistance.
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
GeschäftsführerManaging Director
Leitung Technik & QualitätswesenHead of Technology & Quality Assurance
Umweltbundesamt: 'Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser', (abgerufen am 03.04.2017).Federal Environment Agency: 'Assessment basis for metallic materials in contact with drinking water', (accessed on 03.04.2017).
[pdf] PGFA33-v1.0
Components
Nr. Komponente AnzahlNo. Component Quantity
1 Armatur 11 Faucet 1
2 Madenschraube 42 Grub screw 4
4 Madenschraube 24 Grub screw 2
5 Wandblende 25 Wall cover 2
6 Dichtung 46 Seal 4
7 S-Anschluss 27 S-connector 2
8 Zertifikat unter: 0 www.paulgurkesshop.de8 Certificate under: 0 www.paulgurkesshop.de
Technical Data Ceramic Cartridge
Technische Daten KeramikkartuscheTechnical Data Ceramic Cartridge
KTW-Zulassung für TrinkwasserKTW approval for drinking water
Empfohlener Druck 1-5 BarRecommended pressure 1-5 Bar
Öffnungswinkel 25°Opening angle 25°
Maximale Temperatur 90°Maximum temperature 90°
Lebensdauer 70.000 Zyklen (EN 817)Lifespan 70,000 cycles (EN 817)
Operation
BedienungOperation
• Regeln Sie die Intensität des Wassers mit dem Griff wie in der Abbildung zu sehen. • Regeln Sie die Temperatur des Wassers durch Anwinkeln des Griffes wie abgebildet.• Adjust the intensity of the water with the handle as shown in the illustration. • Adjust the temperature of the water by angling the handle as shown.
Installation Steps
InstallationsschritteInstallation Steps
• Umwickeln Sie die S-Anschlüsse mit Teflonband oder Hanf um diese abzudichten. Drehen Sie diese in die vorhandenen Anschlüsse der Wand. • Montieren Sie die Blenden. • Spülen Sie die Leitung mindestens zwei Minuten, bevor Sie die Armatur an die S-Anschlüsse anschließen.• Wrap the S-connectors with Teflon tape or hemp to seal them. Screw them into the existing wall connections. • Mount the covers. • Flush the line for at least two minutes before connecting the faucet to the S-connectors.
Care Instructions
PflegehinweiseCare Instructions
• Farbige Oberflächen dürfen in keinem Fall mit scheuernden, ätzenden oder alkoholhaltigen Mitteln gereinigt werden. • Spülen Sie das Produkt mit klarem Wasser ab und trocknen es mit einem Mikrofasertuch.• Colored surfaces must not be cleaned with abrasive, corrosive or alcoholic agents. • Rinse the product with clear water and dry it with a microfiber cloth.
PaulGurkes Quality
PaulGurkes QualitätPaulGurkes Quality
• Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. • Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. • Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns.• Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and made using high-quality materials. • Each product undergoes a hand-picked quality control. • If you are not satisfied with our products, please contact us.
Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.We reserve the right to make updates, changes or additions to the information and data provided.
Analyseberichte - PGFA33 - Version 1
Analysis Report
Analysis Report The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The proof of suitability in drinking water installations in accordance with the Drinking Water Ordinance (TrinkwV 2001) is thus demonstrated. The tested material meets the requirements of the Federal Environment Agency regarding "Assessment bases for metallic materials in contact with drinking water" - UBA - Positive List. The material complies, according to the Federal Environment Agency, with the DIN 50930-6 standard, which sets out statements regarding corrosion resistance.
Material
Material CW617N (CuZn40Pb2)
Manufacturer Information
Report Number: #2017-240
Manufacturer Number: PGFA33
EAN: 4250914800777
Company: PaulGurkes GmbH
Street: Klingenbergstr. 12
City: 31139 Hildesheim
Analysis Report XL2-99147
Measurement Number: 240
Mode: Alloys
Measurement Duration: 9.0s
Time: 22.03.2017 13:35:05
Manufacturer Number: pgfa33
User Login: Marc Manusch
Material Suggestion: CW617N_CuZn40Pb2
Element Composition
Element % | ± 2σ | Min | Max
Copper Cu 59.603 | ± 0.624 | 57.000 | 60.000
Zinc Zn 38.107 | ± 0.536 | 37.000 | 41.500
Lead Pb 1.712 | ± 0.177 | 1.600 | 2.200
Tin Sn 0.142 | ± 0.113 | 0.000 | 0.300
Iron Fe 0.104 | ± 0.045 | 0.000 | 0.300
Nickel Ni 0.076 | ± 0.044 | 0.000 | 0.100
Aluminium Al 0.000 | | | 0.050
Signature
Place and Date: Hildesheim, Monday, April 3, 2017
Head of Engineering and Quality: Marc Manusch
Position: Head of Engineering and Quality
Managing Director: Olaf Manusch
Position: Managing Director
References
References: Federal Environment Agency: "Assessment bases for metallic materials in contact with drinking water", (accessed 03.04.2017).

PGFA16

[pdf] PGFA16_v1.1
Product Information
Waschtischarmatur Artikelnummer: PGFA16Washbasin fitting Article number: PGFA16
Components
Komponenten Nr. Komponente Anzahl 1 Armaturkörper 1 2 Dichtung 1 3 Halbmonddichtung 1 4 Halbmond 1 5 Gewindestange 1 6 Mutter 1 7 Flexschläuche 2Components No. Component Quantity 1 Faucet body 1 2 Seal 1 3 Crescent seal 1 4 Crescent 1 5 Threaded rod 1 6 Nut 1 7 Flexible hoses 2
Technical Data
Technische Daten Keramikkartusche KTW-Zulassung für Trinkwasser Empfohlener Druck 1-5 Bar Maximale Temperatur 90° Lebensdauer 200.000 Zyklen (EN 200) Rotation 90° Flexschläuche DVGW geprüft und zugelassenTechnical data Ceramic cartridge KTW approval for drinking water Recommended pressure 1-5 bar Maximum temperature 90° Lifetime 200,000 cycles (EN 200) Rotation 90° Flexible hoses DVGW tested and approved
Operation
Bedienung • Regeln Sie die Intensität des Wassers mit dem Griff in vertikaler Richtung. • Regeln Sie die Temperatur des Wassers in horizontaler Richtung.Operation • Regulate the intensity of the water with the handle in the vertical direction. • Regulate the temperature of the water in the horizontal direction.
Installation Steps
Installationsschritte • Montieren Sie die Armatur wie im Anordnungsplan auf Seite 1. • Ziehen Sie die Flexschläuche an der Armatur handfest an. • Befestigen Sie die Armatur am Waschbecken und schließen Sie die Leitungen an die Eckventile an. • Demontieren Sie den Strahlregler der Armatur und spülen Sie die Leitung mindesten zwei Minuten. • Ziehen Sie die Schläuche erneut handfest an und überprüfen Sie die Montage auf Dichtheit.Installation steps • Mount the fitting as shown in the layout plan on page 1. • Tighten the flexible hoses to the fitting by hand. • Attach the fitting to the washbasin and connect the lines to the angle valves. • Disassemble the jet regulator of the fitting and flush the line for at least two minutes. • Retighten the hoses by hand and check the assembly for leaks.
Installation Notes
Installationshinweise • Beachten Sie bei der Installation alle erforderlichen gesetzlichen und nationalen Bestimmungen (anerkannte Regeln der Technik) und halten Sie diese ein. • Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.Installation notes • When installing, observe all necessary legal and national regulations (recognized rules of technology) and comply with them. • We reserve the right to make updates, changes or additions to the information and data provided.
[pdf] Analysebericht-PGFA16
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested by X-ray fluorescence analysis and yielded the following measurement result.
Bericht-Nr.:Report No.:
Herstellernummer:Manufacturer number:
KupferCopper
ZinkZinc
BleiLead
EisenIron
ZinnTin
AluminiumAluminum
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the Federal Environment Agency regarding the "assessment principles for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information on corrosion resistance.
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Olaf Manusch, GeschäftsführerOlaf Manusch, Managing Director
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Marc Manusch, Leitung Technik & QualitätswesenMarc Manusch, Head of Engineering & Quality
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 04/03/2017).
Analyseberichte - PGFA16 - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The suitability for drinking water installations according to the Drinking Water Regulation (TrinkwV 2001) is thus demonstrated. The tested material complies with the requirements of the Federal Environmental Agency regarding "Assessment basis for metallic materials in contact with drinking water" - UBA positive list. The material meets the DIN 50930-6 standard according to the Federal Environmental Agency, which addresses statements regarding corrosion resistance.
Product Information
Werkstoff: CW617N (CuZn40Pb2) Material: CW617N (CuZn40Pb2)
Herstellernummer: PGFA16 Manufacturer Number: PGFA16
EAN: 4250914800425 EAN: 4250914800425
Bericht-Nr.: #2017-189 Report No.: #2017-189
PaulGurkes GmbH, Klingenbergstr. 12, 31139 Hildesheim PaulGurkes GmbH, Klingenbergstr. 12, 31139 Hildesheim
Measurement No. 189 (pgfa16)
Analysenbericht: XL2-99147 Analysis Report: XL2-99147
Modus: Legierungen Mode: Alloys
Messdauer: 11,3s Measurement Duration: 11.3s
Zeit: 14.03.2017 16:20:21 Time: 14.03.2017 16:20:21
Werkstoffvorschlag: CW617N_CuZn40Pb2 Material Suggestion: CW617N_CuZn40Pb2
User Login: Marc Manusch User Login: Marc Manusch
Measurement Results No. 189
Element: Kupfer (Cu) | Messwert: 59,796 % | Toleranz: ±0,633 | Min: 57,000 | Max: 60,000 Element: Copper (Cu) | Measured Value: 59.796 % | Tolerance: ±0.633 | Min: 57.000 | Max: 60.000
Element: Zink (Zn) | Messwert: 37,440 % | Toleranz: ±0,537 | Min: 37,000 | Max: 41,500 Element: Zinc (Zn) | Measured Value: 37.440 % | Tolerance: ±0.537 | Min: 37.000 | Max: 41.500
Element: Blei (Pb) | Messwert: 1,928 % | Toleranz: ±0,184 | Min: 1,600 | Max: 2,200 Element: Lead (Pb) | Measured Value: 1.928 % | Tolerance: ±0.184 | Min: 1.600 | Max: 2.200
Element: Eisen (Fe) | Messwert: 0,613 % | Toleranz: ±0,084 | Min: 0,000 | Max: 0,300 Element: Iron (Fe) | Measured Value: 0.613 % | Tolerance: ±0.084 | Min: 0.000 | Max: 0.300
Element: Nickel (Ni) | Messwert: 0,094 % | Toleranz: ±0,047 | Min: 0,000 | Max: 0,100 Element: Nickel (Ni) | Measured Value: 0.094 % | Tolerance: ±0.047 | Min: 0.000 | Max: 0.100
Element: Zinn (Sn) | Messwert: 0,000 % | Min: 0,000 | Max: 0,300 Element: Tin (Sn) | Measured Value: 0.000 % | Min: 0.000 | Max: 0.300
Element: Aluminium (Al) | Messwert: 0,000 % | Min: 0,000 | Max: 0,050 Element: Aluminum (Al) | Measured Value: 0.000 % | Min: 0.000 | Max: 0.050
Measurement No. 188 (europa16)
Analysenbericht: XL2-99147 Analysis Report: XL2-99147
Modus: Legierungen Mode: Alloys
Messdauer: 18,0s Measurement Duration: 18.0s

[PDF] Allgemeine Pflegehinweise

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Laden...

3D-Modell wird geladen...

Maus: Drehen | Scrollen: Zoom | Rechtsklick: Verschieben Finger: Drehen | Pinch: Zoom | Zwei Finger: Verschieben