Skip to main content Skip to search Skip to main navigation
Bewertungsdurchschnitt mit

Average rating of 4.9 out of 5 stars

(4.91/5.00) aus insgesamt 2948 Bewertungen
Skip product gallery

Serie

Average rating of 4.9 out of 5 stars

Average rating of 4.8 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 4.9 out of 5 stars

Average rating of 4.9 out of 5 stars

Skip product gallery

Serie

Average rating of 4.9 out of 5 stars

Average rating of 4.8 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 4.9 out of 5 stars

Average rating of 4.9 out of 5 stars

Concealed Mixer Valve

  • Made of solid brass
  • High-quality chrome finish
  • Nostalgia design with modern technology
  • Suitable for 2 outlets, e.g., overhead and hand shower
  • Switching between outlets by pressing the diverter
  • Vibration damper for noise reduction
  • Required base unit PGBASIC
  • Durable ceramic cartridge

Note

This item requires the following accessories:

  • Base unit - Manufacturer number: PGBASIC - EAN: 4250914808827

Versand

  • Versandgewicht: 1.5 Kg
  • Versandart: Paket

Produktsicherheitsverordnung

Angaben zum Hersteller:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 13.05.2026, 20:07:35

[pdf] PGNX2W-v1.0
Components
Nr. Komponente AnzahlNo. Component Quantity
1 Griff 11 Handle 1
2 Madenschraube 12 Grub screw 1
4 Umstellerknopf 14 Diverter knob 1
5 Blende 15 Cover 1
6 Dichtung 16 Seal 1
7 Dichtung 17 Seal 1
8 Schraube 48 Screw 4
9 Fliesenspiegel 19 Tile trim 1
10 Dichtung 110 Seal 1
11 Armatur 111 Fitting 1
12 Dichtung 612 Seal 6
13 Schlüssel 213 Key 2
Zertifikat unter: www.paulgurkesshop.de 1Certificate at: www.paulgurkesshop.de 1
15 Anleitung 115 Instructions 1
Installation Steps
Installationsschritte • Nach der Installation der Unterputz-Box und Prüfung auf Dichtheit ist das Wasser abzustellen. • Entfernen Sie den Schutz der Box. Montieren Sie die Armatur wie im zweiten Schaubild. • Ziehen Sie die Schrauben fest an, vergessen Sie die O-Ringe nicht. • Montieren Sie nun die Abdeckungen wie im dritten Bild. Justieren Sie die Abdeckung, bevor Sie diese fixieren. • Installieren Sie die Blende der Armatur wie im letzten Installationsbild. • Montieren Sie nun den Rest der Armatur.Installation Steps • After installing the concealed box and checking for leaks, turn off the water. • Remove the cover from the box. Mount the fitting as shown in the second diagram. • Tighten the screws, don't forget the O-rings. • Now mount the covers as shown in the third picture. Adjust the cover before fixing it. • Install the cover of the fitting as shown in the last installation picture. • Now mount the rest of the fitting.
Switching Outlets
Ausgänge schalten • Ohne betätigen des Umstellers ist der untere Ausgang des Grundkörpers aktiv (Handbrause). • Durch Drücken des Umstellers ist der obere Ausgang des Grundkörpers aktiv (Kopfbrause).Switching Outlets • Without actuating the diverter, the lower outlet of the basic body is active (hand shower). • By pressing the diverter, the upper outlet of the basic body is active (head shower).
Regulating Water
Wasser regeln • Regeln Sie die Intensität indem Sie den Griff anwinkeln. Durch Bewegen des Griffs nach links (warm) und rechts (kalt) regeln Sie die Temperatur.Regulating Water • Regulate the intensity by angling the handle. Regulate the temperature by moving the handle to the left (warm) and to the right (cold).
Cleaning & Maintenance
Säuberung & Wartung Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten: • Mit sauberem Wasser abspülen & mit Mikrofasertuch trocknen. • Schmutz nur mit milden Reinigungsmitteln entfernen. • Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc. • Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife.Cleaning & Maintenance To ensure consistent quality, please note the following: • Rinse with clean water & dry with a microfiber cloth. • Only remove dirt with mild detergents. • Do not use scouring milk, polishing paste, paper towels, etc. • Do not use any acidic cleaning agents or soap.
PaulGurkes Quality
PaulGurkes Qualität • Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. • Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. • Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns.PaulGurkes Quality • Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and manufactured using high-quality materials. • Each product undergoes a hand-picked quality control. • If you are not satisfied with our products, please contact us.
Disclaimer
Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.We reserve the right to make updates, changes or additions to the information and data provided.
[pdf] Analysebericht-PGNX2W
Analysis Report Header
AnalyseberichtAnalysis Report
Introduction
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2018-909Report No.: #2018-909
Herstellernummer: PGNX2WManufacturer Number: PGNX2W
Material Composition Analysis
Kupfer Cu 60,095 ± 0,549 58,000 63,000Copper Cu 60.095 ± 0.549 58.000 63.000
Zink Zn 38,483 ± 0,485 33,500 41,500Zinc Zn 38.483 ± 0.485 33.500 41.500
Blei Pb 1,231 ± 0,143 0,200 1,400Lead Pb 1.231 ± 0.143 0.200 1.400
Eisen Fe 0,084 ± 0,039 0,000 0,300Iron Fe 0.084 ± 0.039 0.000 0.300
Nickel Ni 0,068 ± 0,039 0,000 0,200Nickel Ni 0.068 ± 0.039 0.000 0.200
Mangan Mn 0,037 ± 0,039 0,000 0,050Manganese Mn 0.037 ± 0.039 0.000 0.050
Zinn Sn 0,000 ± 0,091 0,000 0,500Tin Sn 0.000 ± 0.091 0.000 0.500
Silizium Si 0,000 0,050Silicon Si 0.000 0.050
Aluminium Al 0,300 0,900Aluminum Al 0.300 0.900
Compliance Statement
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Environment Agency (Umweltbundesamt) regarding the "assessment basis for metallic materials in contact with drinking water" - UBA positive list. According to the German Environment Agency, the material meets the DIN 50930-6 standard, which provides information on corrosion resistance.
Material Designation
Werkstoff: CC757S (CuZn39Pb1Al-C)Material: CC757S (CuZn39Pb1Al-C)
Footer Information
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Montag, 8. Oktober 2018Hildesheim, Monday, October 8, 2018
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Technology & Quality Assurance
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am Montag, 8. Oktober 2018).German Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on Monday, October 8, 2018).
[pdf] PGNX2W_Anordnungsplan.pdf
Component List

[PDF] Allgemeine Pflegehinweise

Analyseberichte - PGNX2W - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. The sample was tested by X-ray fluorescence analysis and yielded the following measurement result. The demonstration of suitability in drinking water installations according to the Drinking Water Regulation (TrinkwV 2001) is hereby provided. The tested material complies with the requirements of the Federal Environmental Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environmental Agency, the material meets the DIN 50930-6 standard, which addresses corrosion resistance.
Material and Identification
Werkstoff: CC757S (CuZn39Pb1Al-C) Material: CC757S (CuZn39Pb1Al-C)
Bericht-Nr.: #2018-909 Report No.: #2018-909
Herstellernummer: PGNX2W Manufacturer Number: PGNX2W
EAN: 4250914810318 EAN: 4250914810318
Analysis Report Measured Values
Analysenbericht: XL2-99147 Analysis Report: XL2-99147
Messung Nr.: 909 Measurement No.: 909
Modus: Legierungen Mode: Alloys
Messdauer: 9,0s Measurement Duration: 9.0s
Zeit: 08.10.2018 14:14:47 Time: 08.10.2018 14:14:47
Herstellernummer: pgnx2w Manufacturer Number: pgnx2w
User Login: Marc Manusch User Login: Marc Manusch
Werkstoffvorschlag: CC575S_CuZn39Pb1Al Material Suggestion: CC575S_CuZn39Pb1Al
Element Analysis
Kupfer Cu: 60,095 ± 0,549 (Min: 58,000 | Max: 63,000) Copper Cu: 60.095 ± 0.549 (Min: 58.000 | Max: 63.000)
Zink Zn: 38,483 ± 0,485 (Min: 33,500 | Max: 41,500) Zinc Zn: 38.483 ± 0.485 (Min: 33.500 | Max: 41.500)
Blei Pb: 1,231 ± 0,143 (Min: 0,200 | Max: 1,400) Lead Pb: 1.231 ± 0.143 (Min: 0.200 | Max: 1.400)
Eisen Fe: 0,084 ± 0,039 (Min: 0,000 | Max: 0,300) Iron Fe: 0.084 ± 0.039 (Min: 0.000 | Max: 0.300)
Nickel Ni: 0,068 ± 0,039 (Min: 0,000 | Max: 0,200) Nickel Ni: 0.068 ± 0.039 (Min: 0.000 | Max: 0.200)
Mangan Mn: 0,037 ± 0,039 (Min: 0,000 | Max: 0,050) Manganese Mn: 0.037 ± 0.039 (Min: 0.000 | Max: 0.050)
Zinn Sn: 0,000 ± 0,091 (Min: 0,000 | Max: 0,500) Tin Sn: 0.000 ± 0.091 (Min: 0.000 | Max: 0.500)
Silizium Si: (Min: 0,000 | Max: 0,050) Silicon Si: (Min: 0.000 | Max: 0.050)
Aluminium Al: (Min: 0,300 | Max: 0,900) Aluminum Al: (Min: 0.300 | Max: 0.900)
Contact Information
Geschäftsführer: Olaf Manusch Managing Director: Olaf Manusch
Leitung Technik & Qualitätswesen: Marc Manusch Head of Engineering & Quality Management: Marc Manusch
Adresse: Klingenbergstr. 12, 31139 Hildesheim Address: Klingenbergstr. 12, 31139 Hildesheim
Datum: Hildesheim, Montag, 8. Oktober 2018 Date: Hildesheim, Monday, October 8, 2018
Analyseberichte - PGNX2W - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. The sample was tested using X-ray fluorescence analysis and yielded the following measurement result. The proof of suitability for use in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is hereby established.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA-Positivliste. The tested material complies with the requirements of the Federal Environmental Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list.
Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. The material meets the standard DIN 50930-6 according to the Federal Environmental Agency, which sets forth requirements regarding corrosion resistance.
General Information
Werkstoff: CC575S (CuZn39Pb1Al) Material: CC575S (CuZn39Pb1Al)
Bericht-Nr.: #2017-751 Report No.: #2017-751
Herstellernummer: PGBA2W / PGNX2W Manufacturer Number: PGBA2W / PGNX2W
EAN: 4250914808858 / 4250914810318 EAN: 4250914808858 / 4250914810318
Analysenbericht XL2-99147 Analysis Report XL2-99147
Messung Nr.: 751 Measurement No.: 751
Modus: Legierungen Mode: Alloys
Messdauer: 4,5s Measurement Duration: 4.5s
Zeit: 02.12.2017 12:12:46 Time: 02.12.2017 12:12:46
Herstellernummer pgba2w Manufacturer Number pgba2w
User Login Marc Manusch User Login Marc Manusch
Werkstoffvorschlag: CC575S_CuZn39Pb1Al Material Suggestion: CC575S_CuZn39Pb1Al
Element Analysis
Kupfer Cu 59,658 ± 0,829 58,000 63,000 Copper Cu 59.658 ± 0.829 58.000 63.000
Zink Zn 38,999 ± 0,731 33,500 41,500 Zinc Zn 38.999 ± 0.731 33.500 41.500
Blei Pb 1,172 ± 0,208 0,200 1,400 Lead Pb 1.172 ± 0.208 0.200 1.400
Eisen Fe 0,149 ± 0,069 0,000 0,300 Iron Fe 0.149 ± 0.069 0.000 0.300
Zinn Sn 0,000 ± 0,153 0,000 0,500 Tin Sn 0.000 ± 0.153 0.000 0.500
Nickel Ni 0,000 ± 0,083 0,000 0,200 Nickel Ni 0.000 ± 0.083 0.000 0.200
Mangan Mn 0,000 ± 0,097 0,000 0,050 Manganese Mn 0.000 ± 0.097 0.000 0.050
Silizium Si 0,000 0,050 Silicon Si 0.000 0.050
Aluminium Al 0,300 0,900 Aluminum Al 0.300 0.900
Contact and Validity Information
Olaf Manusch Geschäftsführer Olaf Manusch Managing Director
Marc Manusch Leitung Technik & Qualitätswesen Marc Manusch Head of Engineering & Quality Management
Klingenbergstr. 12 31139 Hildesheim Klingenbergstr. 12 31139 Hildesheim
Hildesheim, 2. Dezember 2017 Hildesheim, December 2, 2017
Farbe: Chrom

1 of 1 reviews

Average rating of 5 out of 5 stars


100%

0%

0%

0%

0%


Leave a review!

Share your experiences with other customers.


1 review

December 2, 2021 - Reinhold Kahl 🇩🇪 Deutschland
Verifizierter Kauf

Review with rating of 5 out of 5 stars

High Quality!
KI-übersetzt (Originalsprache: de-DE) Original anzeigen
Laden...

3D-Modell wird geladen...

Maus: Drehen | Scrollen: Zoom | Rechtsklick: Verschieben Finger: Drehen | Pinch: Zoom | Zwei Finger: Verschieben